Dynamic deformation characteristics of porcine aortic valve leaflet under normal and hypertensive conditions

Author:

Yap Choon Hwai1,Kim Hee-Sun2,Balachandran Kartik1,Weiler Michael1,Haj-Ali Rami23,Yoganathan Ajit P.1

Affiliation:

1. School of Biomedical Engineering, Georgia Institute of Technology and Emory University, and

2. School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia; and

3. School of Mechanical Engineering, Tel-Aviv University, Ramat Aviv, Israel

Abstract

Calcific aortic valve (AV) disease has a high prevalence in the United States, and hypertension is correlated to early onset of the disease. The cause of the disease is poorly understood, although biological and remodeling responses to mechanical forces, such as membrane tension, have been hypothesized to play a role. The mechanical behavior of the native AV has, therefore, been the focus of many recent studies. In the present study, the dynamic deformation characteristics of the AV leaflet and the effects of hypertension on leaflet deformation are quantified. Whole porcine aortic roots were trimmed and mounted in an in vitro pulsatile flow loop and subjected to normal (80/120 mmHg), hypertensive (120/160 mmHg), or severe hypertensive (150/190 mmHg) conditions. Local valve leaflet deformations were calculated with dual-camera photogrammetry method: by tracking the motion of markers placed on the AV leaflets in three dimensions and calculating their spatial deformations. The results demonstrate that, first, during diastole, high transvalvular pressure induces a stretch waveform which plateaus over the diastolic duration in both circumferential and radial directions. During systole, the leaflet stretches in the radial direction due to forward flow drag forces but compresses in the circumferential direction in a manner in agreement with Poisson's effect. Second, average diastolic and systolic stretch ratios were quantified in the radial and circumferential directions in the base and belly region of the leaflet, and diastolic stretch was found to increase with increasing pressure conditions.

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

Cited by 63 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3