Using velocity-pressure loops in the operating room: a new approach of arterial mechanics for cardiac afterload monitoring under general anesthesia

Author:

Hong A.12ORCID,Joachim J.12,Buxin C.1,Levé C.1,Le Gall A.134,Millasseau S.5,Mateo J.1,Civelli V.6,Serrano J.1,Mebazaa A.12,Gayat E.12,Vallée F.1234

Affiliation:

1. Department of Anesthesiology and Intensive Care, Lariboisière-Saint Louis Hospitals, Paris, France

2. Inserm, UMRS-942, Paris Diderot University, Paris, France

3. Mathematical and Mechanical Modeling with Data Interaction in Simulations for Medicine, Inria, Université Paris-Saclay, Palaiseau, France

4. Solid Mechanics Laboratory, Ecole Polytechnique, Centre National de la Recherche Scientifique, Palaiseau, France

5. Pulse Wave Consulting, Saint-Leu-La-Forêt, France

6. Department of Neuroradiology, Lariboisière Hospital, Paris, France

Abstract

Cardiac afterload is usually assessed in the ascending aorta and can be defined by the association of peripheral vascular resistance (PVR), total arterial compliance (Ctot), and aortic wave reflection (WR). We recently proposed the global afterload angle (GALA) and β-angle derived from the aortic velocity-pressure (VP) loop as continuous cardiac afterload monitoring in the descending thoracic aorta. The aim of this study was to 1) describe the arterial mechanic properties by studying the velocity-pressure relations according to cardiovascular risk (low-risk and high-risk patients) in the ascending and descending thoracic aorta and 2) analyze the association between the VP loop (GALA and β-angle) and cardiac afterload parameters (PVR, Ctot, and WR). PVR, Ctot, WR, and VP loop parameters were measured in the ascending and descending thoracic aorta in 50 anesthetized patients. At each aortic level, the mean arterial pressure (MAP), cardiac output (CO), and PVR were similar between low-risk and high-risk patients. In contrast, Ctot, WR, GALA, and β-angle were strongly influenced by cardiovascular risk factors regardless of the site of measurement along the aorta. The GALA angle was inversely related to aortic compliance, and the β-angle reflected the magnitude of wave reflection in both the ascending and descending aortas ( P < 0.001). Under general anesthesia, the VP loop can provide new visual insights into arterial mechanical properties compared with the traditional MAP and CO for the assessment of cardiac afterload. Further studies are necessary to demonstrate the clinical utility of the VP loop in the operating room. NEW & NOTEWORTHY Our team recently proposed the global afterload angle (GALA) and β-angle derived from the aortic velocity-pressure (VP) loop as continuous cardiac afterload monitoring in the descending thoracic aorta under general anesthesia. However, the evaluation of cardiac afterload at this location is unusual. The present study shows that VP loop parameters can describe the components of cardiac afterload both in the ascending and descending thoracic aorta in the operating room. Aging and cardiovascular risk factors strongly influence VP loop parameters. The VP loop could provide continuous visual additional information on the arterial system than the traditional mean arterial pressure and cardiac output during the general anesthesia.

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3