Normal tissue objective (NTO) tool in Eclipse treatment planning system for dose distribution optimization

Author:

Indrayani Liza1,Anam Choirul1,Sutanto Heri1,Subroto Rinarto2,Dougherty Geoff3

Affiliation:

1. Department of Physics, Faculty of Sciences and Mathematics , Diponegoro University , Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Central Java , Indonesia .

2. Regional General Hospital of NTB Province , 84371, Mataram, West Nusa Tenggara , Indonesia

3. Department of Applied Physics and Medical Imaging , California State University Channel Islands , Camarillo , , USA

Abstract

Abstract Introduction: The purpose of this study was to determine the best normal tissue objective (NTO) values based on the dose distribution from brain tumor radiation therapy. Material and methods: The NTO is a constraint provided by Eclipse to limit the dose to normal tissues by steepening the dose gradient. The multitude of NTO setting combinations necessitates optimal NTO settings. The Eclipse supports manual and automatic NTOs. Fifteen patients were re-planned using NTO priorities of 1, 50, 100, 150, 200, and 500 in combination with dose fall-offs of 0.05, 0.1, 0.2, 0.3, 0.5, 1 and 5 mm-1. NTO distance to planning target volume (PTV), start dose, and end dose were 1 mm, 105%, and 60%, respectively, for all plans. In addition, planning without the NTO was arranged to find out its effect on planning. The prescription dose covered 95% of the PTV. Planning was evaluated using several indices: conformity index (CI), homogeneity index (HI), gradient index (GI), modified gradient index (mGI), comprehensive quality index (CQI), and monitor unit (MU). Differences among automatic NTO, manual NTO, and without NTO were evaluated using the Wilcoxon signed-rank test. Results: Comparisons obtained without and with manual NTO were: CI of 0.77 vs. 0.96 (p = 0.002), GI of 4.52 vs. 4.69 (p = 0.233), mGI of 4.93 vs. 3.95 (p = 0.001), HI of 1.10 vs. 1.10 (p = 0.330), and MU/cGy of 3.44 vs. 3.42 (p = 0.460). Planning without NTO produced a poor conformity index. Comparisons of automatic and manual NTOs were: CI of 0.92 vs. 0.96 (p = 0.035), GI of 5.25 vs. 4.69 (p = 0.253), mGI of 4.46 vs. 3.95 (p = 0.001), HI of 1.09 vs. 1.10 (p = 0.004), MU/cGy of 3.31 vs. 3.42 (p = 0.041). Conclusions: Based on these results, manual NTO with a priority of 100 and dose fall-off 0.5 mm-1 was optimal, as indicated by the high dose reduction in normal tissue.

Publisher

Walter de Gruyter GmbH

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3