Quantitative analysis of Gamma Knife stereotactic radiosurgery for uveal melanoma

Author:

Bisht Raj Kishor1,Natanasabapathi Gopishankar2,Kale Shashank Sharad1

Affiliation:

1. Department of Neurosurgery , All India Institute of Medical Sciences , New Delhi , India

2. Dr B.R. Ambedkar Institute Rotary Cancer Hospital, All India Institute of Medical Sciences , New Delhi , India

Abstract

Abstract The purpose of the study was to analyze single fraction Gamma Knife stereotactic radiosurgery (SRS) for uveal melanoma (UM). In the treatment of UMs, the dose distribution exhibited by an irregular eye surface has more calculation uncertainty. A tissue-equivalent bolus was placed on the left eye surface of a human head-shaped phantom. It was assumed that the treated eye is fixed using retrobulbar anesthesia and suture on extraocular muscles for phantom study. Leksell stereotactic frame was fixed around phantom’s head and the stereotactic computed tomography (CT) was performed. Two sets of scans were acquired (a) without bolus and (b) with a bolus of 1.0 cm thickness. These scans were transferred into a treatment planning system (TPS). The skull contouring was performed using stereotactic CT images. The target, visual pathways, and eye lens were delineated in stereotactic CT space created on TPS. A clinical relevant plan was designed on the CT study set “a” to deliver a radiation dose of 30Gy at tumor margin. The plan superimposed over CT study set “b” and compiled for convincing treatment strategy. The tumor coverage was 95% at 50% prescription isodose line. The conformity index, selectivity and the gradient index were 1.27, 0.80 and 3.28 respectively. The left optic nerve and eye lens received a maximum dose of 11.1 Gy and 11.0 Gy respectively. The treatment plan overlay showed similar planning indices and critical organ doses. The plan comparison showed: an irradiated volume received the radiation dose > 15 Gy varies < 1.0% whereas the volume received < 15 Gy were larger (> 1.0%) in the study set “b”. The distant lateral points from the target volume which describe the phantom’s eyelid showed a radiation dose of 3.2 Gy - 2.5 Gy. The doses to these points were misled and ignored in the CT study set “a”. The eye bolus provides better dosimetric information in the estimation of low dose areas which is commonly misled on TPS in SRS planning for UMs.

Publisher

Walter de Gruyter GmbH

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3