Evaluation of effective dose and entrance skin dose in digital radiology

Author:

Shamsi Khatereh1,Monfared Ali Shabestani23,Deevband Mohammad Reza4,Mohsenzadeh Behzad4,Ghorbani Mahdi4,Gorji Kourosh Ebrahimnejad2,Niksirat Fatemeh2

Affiliation:

1. Student Research Committee , Babol University of Medical Sciences , Babol , Iran

2. Department of Medical Physics , Radiobiology and Radiation Protection, School of Medicine , Babol University of Medical Sciences , Babol , Iran

3. Cancer Research Center, Health Research Institute , Babol University of Medical Sciences , Babol , Iran

4. Biomedical Engineering and Medical Physics Department , School of Medicine , Shahid Beheshti University of Medical Sciences , Tehran , Iran

Abstract

Abstract Background: Ionizing radiation has an indispensable role in diagnostic radiology and clinical treatments. Apparently, medical exposure in diagnostic radiology pertains to be the preeminent man-made source of radiation. Objective: The aim of the present scientific study is to calculate the Entrance Surface Dose (ESD) and Effective Dose (ED) in digital radiography in Mazandaran province. Materials and methods: The study was performed on 3600 patients in digital X-ray rooms 15 hospitals and the required data were collected from two age groups (10>15 years and adults) in each projection. Based on the results of this study, ESD and ED were calculated for skull (PA), skull (lateral), cervical spine (AP), cervical spine (lateral), chest (PA), chest (lateral), abdomen (AP), lumbar spine (AP), lumbar spine (lateral), pelvis (AP), thoracic spine (AP) and thoracic spine (lateral) examinations. It was calculated using PCXMC software (version 2.0). Results: In this study, mean ESDs for the 10-15 year group varied from 0.97±0.21 mGy to 3.62±1.38 mGy for chest (PA) and lumbar spine (lateral), respectively. For the adult group varied from 1.05±0.31 to 3.85±1.44 for cervical spine (AP) and lumbar spine (lateral), respectively. And also ED value was from in the range of 10.40 µSv to 378.46 µSv for skull (PA) 10-15 year group and abdomen adults, respectively Conclusion: This survey revealed a significant variation in the radiation dose of digital radiology examinations among hospitals in Mazandaran province. Application of a dose reference level (DRL) could be an optimization procedure for reducing the patient’s dose in Mazandaran province.

Publisher

Walter de Gruyter GmbH

Reference21 articles.

1. [1] Bair W. Overview of ICRP respiratory tract model. Radiation Protection Dosimetry. 1991;38(1-3):147-152.

2. [2] Hall EJ, Brenner DJ. Cancer risks from diagnostic radiology. Br J Radiol. 2008;81(965):362-378.

3. [3] Giczi F, Pellet S, Mclean I D, Meghzifene A. Testing of the implementation of the code of practice on dosimetry in X-ray diagnostic radiology: Hungarian contribution. 2008. IRPA 12: 12. International congress of the International Radiation Protection Association (IRPA): Strengthening radiation protection worldwide, Buenos Aires (Argentina), 19-24 Oct 2008

4. [4] Ross BC, Dixon DW. Exposure to radon in above ground workplaces the experience in great britain (GB). In: 8. International congress of the International Radiation Protection Association (IRPA8). 1992.

5. [5] Pahade JK, Trout AT, Zhang B, et al. What patients want to know about imaging examinations: a multiinstitutional us survey in adult and pediatric teaching hospitals on patient preferences for receiving information before radiologic examinations. Radiology. 2018;287(2):554-562.

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献