Radiation Dose and Image Quality with Exposure Factor Variation Using a Virtual Grid in Digital Radiography

Author:

Fitrus Ardoni 1,Lina Choridah 2,Edy Susanto 2,Muhammad Irsal 3

Affiliation:

1. Postgraduate Diagnostic Imaging Program, Health Polytechnic of Semarang, Semarang, Indonesia
Department of Diagnostic Imaging and Radiotherapy, Health Polytechnic of Ministry of Health Jakarta II, Jakarta, Indonesia

2. Department of Diagnostic Imaging and Radiotherapy, Health Polytechnic of Semarang, Semarang, Indonesia

3. Department of Diagnostic Imaging and Radiotherapy, Health Polytechnic of Ministry of Health Jakarta II, Jakarta, Indonesia

Abstract

Digital radiography technology provides many advantages. However, there are still frequent repetitions of inspections due to failure to determine the exposure factor due to a decrease in image quality. Virtual Grid is a digital radiographic image processing technology that converts image quality that is deteriorating due to X-ray scattering to better image quality by reducing the effects of X-ray scattering. Application of a virtual grid can contribute to improving image quality and increasing the procedural efficiency of the workflow in a radiographic examination. This study uses a research-experimental design, with a One-Shot Case Study. The sample selection of 60 samples was carried out randomly by judgmental or purposive sampling. The sampling technique was carried out with specific considerations for the research objectives to determine the optimal exposure factor by using a virtual grid for the skull, lumbar, and pelvic radiographic examinations. Then, it was analyzed quantitatively and qualitatively visually by three radiologists—a bivariate analysis of data using one-way ANOVA. Qualitative analysis was carried out as well as a test. Feel free to assess the agreement of the informants. Results In the quantitative and qualitative analysis, the exposure factor and the ideal virtual grid ratio for optimization are skull AP: 106 kV, 2 mAs, ratio 14:1, skull lateral: 106 kV, 1.25 mAs, ratio 14:1, skull lumbar AP: 106 kV, 4 mAs, ratio 14:1, skull lumbar lateral: 113 kV, 6.3 mAs, 10:1 ratio, and pelvis AP: 92 kV, 8 mAs, 14:1 ratio.

Publisher

Technoscience Academy

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3