Evaluation of radiographers’ and CT technologists’ knowledge regarding CT exposure parameters

Author:

Mahmoudi Farshid1,Naserpour Mozafar2,Farzanegan Zahra3,Davudian Talab Amirhossein4

Affiliation:

1. Isfahan University of Medical Sciences , Isfahan , Iran

2. Department of Radiology Technology, Behbahan Faculty of Medical Sciences , Behbahan , Iran

3. Jundishapur University of Medical Sciences , Ahvaz , Iran

4. Oil Industries Commissioning and Operation (OICO) , Assaluyeh , Iran

Abstract

Abstract Introduction: Since the CT operators play an important role in the diagnosis and treatment of diseases and exposing the patients to radiation exposure, they must be aware of all CT parameters which affect the image quality and patient dose and update their knowledge in parallel with the progresses in CT technology. Therefore, the knowledge of radiographers and CT technologists regarding the CT parameters was assessed in this study to identify and resolve any potential deficiencies. Material and methods: This study was conducted in 2018 among 113 radiographers and 103 CT technologists in Khuzestan province using a three-part questionnaire containing demographic characteristics, general opinion on CT scan dose and questions assessing technologists’ knowledge of CT exposure parameters. Data were analyzed using SPSS software. Results: Total knowledge scores of radiographers and CT technologists about CT exposure parameters were 36 and 42, respectively. The highest knowledge score among technologist was the knowledge of changing parameters based on patient characteristics and the lowest was in the field of awareness of noise index and diagnostic reference levels. Conclusion: Total knowledge scores of radiographers and CT technologists about different scan parameters affecting dose and image quality was very low. Reviewing and updating the content of academic education and holding retraining courses are suggested.

Publisher

Walter de Gruyter GmbH

Reference39 articles.

1. [1] Pelc NJ. Recent and future directions in CT imaging. Ann Biomed Eng. 2014;42(2):260-268.10.1007/s10439-014-0974-z

2. [2] Sources and Effects of Ionizing Radiation: United Nations Scientific Committee on the Effects of Atomic Radiation: UNSCEAR 2008 Report to the General Assembly, with Scientific Annexes. United Nations, New York. 2008.

3. [3] 2014 CT Market Report Outlook. IMV Medical Information Division. Des Plaines (IL): IMV Medical Information Division; 2014.

4. [4] CT Benchmark Report 2007. IMV Medical Information Division. Des Plaines (IL): IMV Medical Information Division; 2007.

5. [5] Bellolio MF, Bellew SD, Sangaralingham LR, et al. Access to primary care and computed tomography use in the emergency department. BMC Health Serv Res. 2018;18(1):154.10.1186/s12913-018-2958-4

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3