Determining optimum wavelength of ultraviolet rays to pre-exposure of non-uniformity error correction in Gafchromic EBT2 films

Author:

Katsuda Toshizo1,Gotanda Rumi2,Gotanda Tatsuhiro2,Akagawa Takuya3,Tanki Nobuyoshi1,Kuwano Tadao4,Noguchi Atsushi1,Yabunaka Kouichi5

Affiliation:

1. Faculty of Health Sciences, Butsuryo College of Osaka , 3-33, Otorikita-machi Nishi-ku, Sakai-city, Osaka , 593-8328 , Japan

2. Faculty of Health Science and Technology , Kawasaki University of Medical Welfare , Okayama , Japan

3. Department of Radiological Technology , Tokushima Red Cross Hospital, 103, Irinokuchi, Komatsujshima, Tokushima , 773-8502 , Japan

4. Graduate School of Health Sciences , Okayama University , 2-5-1, Shikata-cyo, Kita-ku, Okayama-city, Okayama , 700-8558 , Japan

5. Graduate School of Medicine , the University of Tokyo , 7-3-1 Hongo, Bunkyou-Ku, Tokyo , 113-0033 , Japan

Abstract

Abstract Gafchromic films have been used to measure X-ray doses in diagnostic radiology such as computed tomography. The double-exposure technique is used to correct non-uniformity error of Gafchromic EBT2 films. Because of the heel effect of diagnostic x-rays, ultraviolet A (UV-A) is intended to be used as a substitute for x-rays. When using a UV-A light-emitting diode (LED), it is necessary to determine the effective optimal UV wavelength for the active layer of Gafchromic EBT2 films. This study evaluated the relation between the increase in color density of Gafchromic EBT2 films and the UV wavelengths. First, to correct non-uniformity, a Gafchromic EBT2 film was pre-irradiated using uniform UV-A radiation for 60 min from a 72-cm distance. Second, the film was irradiated using a UV-LED with a wavelength of 353-410 nm for 60 min from a 5.3-cm distance. The maximum, minimum, and mean ± standard deviation (SD) of pixel values of the subtraction images were evaluated using 0.5 inches of a circular region of interest (ROI). The highest mean ± SD (8915.25 ± 608.86) of the pixel value was obtained at a wavelength of 375 nm. The results indicated that 375 nm is the most effective and sensitive wavelength of UV-A for Gafchromic EBT2 films and that UV-A can be used as a substitute for x-rays in the double-exposure technique.

Publisher

Walter de Gruyter GmbH

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Ultraviolet ray irradiation duration for the pre-exposure of Gafchromic EBT2;Polish Journal of Medical Physics and Engineering;2018-12-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3