Abstract Background The aim of the study was to present dosimetric comparison of image guided high-dose-rate brachytherapy (IGBT) with volumetric modulated arc therapy (VMAT) for head and neck cancer regarding conformity of dose distribution to planning target volume (PTV) and doses to organs at risk (OARs). Patients and methods Thirty-eight consecutive patients with T1-4 mobile tongue, floor of mouth and base of tongue cancer treated with IGBT were selected. For these patients additional VMAT treatment plans were also prepared using identical computed tomography data. OARs and PTV related parameters (e.g. V98, D0.1cm3, Dmean, etc.) were compared. Results Mean V98 of the PTV was 90.2% vs. 90.4% (p > 0.05) for IGBT and VMAT, respectively. Mean D0.1cm3 to the mandible was 77.0% vs. 85.4% (p < 0.05). Dmean to ipsilateral and contralateral parotid glands was 4.6% vs. 4.6% and 3.0% vs. 3.9% (p > 0.05). Dmean to ipsilateral and contralateral submandibular glands was 16.4% vs. 21.9% (p > 0.05) and 8.2% vs. 16.9% (p < 0.05), respectively. Conclusions Both techniques showed excellent target coverage. With IGBT dose to normal tissues was lower than with VMAT. The results prove the superiority of IGBT in the protection of OARs and the important role of this invasive method in the era of new external beam techniques.

Publisher

Walter de Gruyter GmbH

Subject

Radiology, Nuclear Medicine and imaging,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3