Dosimetric comparison of postoperative interstitial high-dose-rate brachytherapy and modern external beam radiotherapy modalities in tongue and floor of the mouth tumours in terms of doses to critical organs

Author:

Ferenczi Örs1,Major Tibor123,Fröhlich Georgina14,Béla Dalma1,Tódor Szabolcs1,Polgár Csaba123,Akiyama Hironori5,Bukovszky Botond126,Takácsi-Nagy Zoltán123

Affiliation:

1. Centre of Radiotherapy , National Institute of Oncology , Budapest , Hungary

2. Department of Oncology , Semmelweis University , Budapest , Hungary

3. National Tumour Biology Laboratory , National Institute of Oncology , Budapest , Hungary

4. Eötvös Loránd University , Faculty of Science , Budapest , Hungary

5. Department of Oral Radiology , Osaka Dental University , Osaka , Japan

6. Department of Oral Diagnostics , Semmelweis University , Budapest , Hungary

Abstract

Abstract Background The aim of the study was to dosimetrically compare interstitial high-dose-rate (HDR) brachytherapy (BT) and modern external beam radiotherapy modalities, as volumetric modulated arc therapy (VMAT) and stereotactic radiotherapy with Cyberknife (CK) of tumours of the tongue and floor of the mouth in terms of dose to the critical organs. Patients and methods In National Institute of Oncology, Budapest, between March 2013 and August 2022 twenty patients (11 male/9 female) with stage T1–3N0M0 tongue (n = 14) and floor of mouth (n = 6) tumours received postoperative radiotherapy because of close/positive surgical margin and/or lymphovascular and/or perineural invasion. High-dose-rate interstitial brachytherapy applying flexible plastic catheters with a total dose of 15 × 3 Gy was used for treatment. In addition to BT plans VMAT and stereotactic CK plans were also made in all cases, using the same fractionation scheme and dose prescription. As for the organs at risk, the doses to the mandible, the ipsilateral and the contralateral salivary glands were compared. Results The mean volume of the planning target volume (PTV) was 12.5 cm3, 26.5 cm3 and 17.5 cm3 in BT, VMAT and CK techniques, respectively, due to different safety margin protocols. The dose to the mandible was the most favourable with BT, as for the salivary glands (parotid and submandibular) the CK technique resulted in the lowest dose. The highest dose to the critical organs was observed with the VMAT technique. The mean values of D2cm3 and D0.1cm3 for the critical organs were as follows for BT, VMAT and CK plans: 47.4% and 73.9%, 92.2% and 101.8%, 68.4% and 92.3% for the mandible, 4.8% and 6.7%, 7.3% and 13.8%, 2.3% and 5.1% for the ipsilateral parotid gland, 3.5% and 4.9%, 6.8% and 10.9%, 1.5% and 3.3% for the contralateral parotid gland, 7.3% and 9.4%, 9.0% and 14.3%, 3.6% and 5.6% for the contralateral submandibular gland. Conclusions The present results confirm that BT, despite being an invasive technique, is dosimetrically clearly beneficial in the treatment of oral cavity tumours and is a modality worth considering when applying radiotherapy, not only as definitive treatment, but also postoperatively. The use of the CK in the head and neck region requires further investigation.

Publisher

Walter de Gruyter GmbH

Subject

Radiology, Nuclear Medicine and imaging,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3