A modified digital functional reach test device using an ultrasonic sensor for balance assessment: A test of validity and reliability

Author:

Hanphitakphong Panida1,Poomsalood Somruthai1,Chamroon Chakkapong2,Udomkichpagon Palagon1

Affiliation:

1. Department of Physical Therapy, School of Allied Health Sciences , University of Phayao , Thailand

2. Department of Mechanical Engineering, Faculty of Engineering , Chiang Mai University , Thailand

Abstract

Abstract Study aim: Evaluation of dynamic balance is inferred to be compulsory for fall prevention in the elderly. Therefore, this study aimed to develop a modified digital functional reach test device using an ultrasonic sensor for balance assessment and to test validity and reliability of the newly developed tool to qualify psychometric properties. Material and methods: This study was a cross-sectional study of a convenient sample including 50 participants both males and females. Mean age of the participants was 51.20 ± 19.30 years. Reliability of the newly developed device was analysed using the intraclass correlation coefficient (ICC) and standard error of measurement (SEM). The criterion validity was also investigated using a yardstick mounted on the wall at a level of shoulder together with the MaxTraq® 2D motion analysis software. The modified digital functional reach test device using an ultrasonic sensor was correlated with the conventional FRT and the MaxTraq® 2D motion analysis. Results: The results presented that test-retest reliability of the modified digital functional reach test device was good reliability (ICC = 0.76) and low standard error of measurement (1.41) was found for test-retest reliability. The degree of agreement between the modified device, the conventional FRT, and the MaxTraq® 2D motion analysis was high (r = 0.71 and 0.77 respectively). Conclusions: The findings suggested that the modified digital functional reach test device using an ultrasonic sensor was a valid and reliable instrument for fall risk screening towards functional reach distance.

Publisher

Walter de Gruyter GmbH

Subject

Orthopedics and Sports Medicine,Physical Therapy, Sports Therapy and Rehabilitation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3