Dual-Energy Spectral Computed Tomography: Comparing True and Virtual Non Contrast Enhanced Images
Author:
Širůčková Kateřina1, Marcoň Petr1, Dostál Marek2, Širůčková Anna1, Dohnal Přemysl1
Affiliation:
1. Brno University of Technology , Faculty of Electrical Engineering and Communication , Technicka, 12 , , Brno , Czech Republic 2. University Hospital Brno and Masaryk University , Department of Radiology and Nuclear Medicine , Jihlavska, 340/20 , , Brno , Czech Republic
Abstract
Abstract
Spectral computed tomography (CT) imaging is one of several image reconstruction techniques based on the use of dual-layer CT. The intensity and attenuation of the radiation are measured in relation to different wavelengths, and such a procedure results in complex three-dimensional (3D) imaging and (pseudo) color adjustment of the soft tissue. This paper compares true non-contrast (TNC) enhanced images with virtual non-contrast (VNC) enhanced ones. Virtual native images are acquired by means of spectral computed tomography, and it has been suggested that VNCs could potentially substitute real native images to reduce significantly the total radiation dose from multiphase spectral CT. A comparison was performed by defining certain parameters that represent the difference between the measured and the calculated values in the images. The parameters included the mean value and standard deviation of the computed tomography number, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). All of these items were analyzed via statistical tests using p-value. The results are interpreted and correlated with those presented by other authors, who, however, did not make an examination on a comprehensive basis - five tissues simultaneously by using a single device. Prospectively, if analogies were found between the two types of images, it would be possible to skip the TNC image, thus markedly reducing the radiation dose for the patient.
Publisher
Walter de Gruyter GmbH
Subject
Instrumentation,Biomedical Engineering,Control and Systems Engineering
Reference28 articles.
1. [1] Sauter, A.P., Muenzel, D., Dangelmaier, J., Braren, R., Pfeiffer, F., Rummeny, E.J., Noël, P.B., Fingerle, A.A. (2018). Dual-layer spectral computed tomography: Virtual non-contrast in comparison to true non-contrast images. European Journal of Radiology, 104, 108-114. https://doi.org/10.1016/j.ejrad.2018.05.00729857855 2. [2] Hua, C.H., Shapira, N., Merchant, T.E., Klahr, P., Yagil, Y. (2018). Accuracy of electron density, effective atomic number, and iodine concentration determination with a dual-layer dual-energy computed tomography system. Medical Physics, 45 (6), 2486-2497. https://doi.org/10.1002/mp.1290329624708 3. [3] Si-Mohamed, S., Dupuis, N., Tatard-Leitman, V. et al. (2019). Virtual versus true non-contrast dual-energy CT imaging for the diagnosis of aortic intramural hematoma. European Radiology, 29, 6762-6771. https://doi.org/10.1007/s00330-019-06322-531264015 4. [4] Fieselmann, A., Kowarschik, M., Ganguly, A., Hornegger, J., Fahrig, R. (2011). Deconvolution-based CT and MR brain perfusion measurement: Theoretical model revisited and practical implementation details. International Journal of Biomedical Imaging, 2011, 467563. https://doi.org/10.1155/2011/467563316672621904538 5. [5] Coche, E. (2019). Spectral CT Clinical Case Collection: Technical Aspects of Spectral CT. Philips Health System.
|
|