Abstract
Abstract
Bioimpedance measurements use current or voltage sources to inject an excitation signal into the body. These sources require a high bandwidth, typically from 1 kHz to 1 MHz. Besides a low common mode, current limitation is necessary for patient safety. In this paper, we compare a symmetric enhanced Howland current source (EHCS) and a symmetric voltage source (VS) based on a non-inverting amplifier between 1 kHz and 1 MHz. A common mode reduction circuit has been implemented in both sources. The bandwidth of each source was optimized in simulations and achieved a stable output impedance over the whole frequency range. In laboratory measurements, the output impedance of the EHCS had its -3 dB point at 400 kHz. In contrast, the VS reached the +3 dB point at 600 kHz. On average over the observed frequency range, the active common mode compensation achieved a common mode rejection of -57.7 dB and -71.8 dB for the EHCS and VS, respectively. Our modifications to classical EHCS and VS circuits achieved a low common mode signal between 1 kHz and 1 MHz without the addition of complex circuitry, like general impedance converters. As a conclusion we found VSs to be superior to EHCSs for bioimpedance spectroscopy due to the higher bandwidth performance. However, this only applies if the injected current of the VS can be measured.
Subject
Biomedical Engineering,Biophysics
Reference24 articles.
1. Nguyen DT, Kosobrodov R, Barry MA, Chik W, Jin C, Oh TI, Thiagalingam A, and McEwan A. Electrode-skin contact impedance: In vivo measurements on an ovine model. Journal of Physics: Conference Series 2013, 434, 10.1088/1742-6596/434/1/012023
2. Ackmann JJ. Complex bioelectric impedance measurement system for the frequency range from 5 Hz to 1 MHz. Annals of biomedical engineering 1993, 21.135–46, 10.1007/BF02367609
3. Bouchaala D. Investigation of Current Excitation for Personal Health and Biological Tissues Monitoring. Vol. Volume 1, Scientific Reports on Measurement and Sensor Technology. Chemnitz: Universitätsverlag Chemnitz, 2016, Available from: https://nbn-resolving.org/urn:nbn:de:bsz:ch1-qucosa-204801
4. Naranjo-Hernández D, Reina-Tosina J, and Min M. Fundamentals, recent advances, and future challenges in bioimpedance devices for healthcare applications. Journal of Sensors 2019, 2019.42, 10 , 1155/2019/9210258
5. Cole KS and Cole RH. Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics. The Journal of Chemical Physics 1941, 9.341–51, 10.1063/1.1750906,arXiv:arXiv:1011.1669v3
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献