Affiliation:
1. Division of Fundamental Engineering, Graduate School of Science and Engineering , Chiba University , Chiba , Japan
Abstract
Abstract
The image reconstruction in electrical impedance tomography (EIT) has low accuracy due to the approximation error between the measured voltage change and the approximated voltage change, from which the object cannot be accurately reconstructed and quantitatively evaluated. A voltage approximation model based on object-oriented sensitivity matrix estimation (OO-SME model) is proposed to reconstruct the image with high accuracy. In the OO-SME model, a sensitivity matrix of the object-field is estimated, and the sensitivity matrix change from the background-field to the object-field is estimated to optimize the approximated voltage change, from which the approximation error is eliminated to improve the reconstruction accuracy. Against the existing linear and nonlinear models, the approximation error in the OO-SME model is eliminated, thus an image with higher accuracy is reconstructed. The simulation shows that the OO-SME model reconstructs a more accurate image than the existing models for quantitative evaluation. The relative accuracy (RA) of reconstructed conductivity is increased up to 83.98% on average. The experiment of lean meat mass evaluation shows that the RA of lean meat mass is increased from 7.70% with the linear model to 54.60% with the OO-SME model. It is concluded that the OO-SME model reconstructs a more accurate image to evaluate the object quantitatively than the existing models.
Subject
Biomedical Engineering,Biophysics
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献