Three-dimensional MRI evaluation of the effect of bladder volume on prostate translocation and distortion

Author:

Snoj Ziga123,Gill Andrew B.14,Rundo Leonardo15,Sushentsev Nikita1,Barrett Tristan16

Affiliation:

1. Department of Radiology, Addenbrooke’s Hospital and University of Cambridge , Cambridge , UK

2. Radiology Institute, University Medical Centre Ljubljana , Ljubljana , Slovenia

3. Faculty of Medicine, University of Ljubljana , Ljubljana , Slovenia

4. Department of Medical Physics, Cambridge University Hospitals , Cambridge , UK

5. Cancer Research UK Cambridge Centre , Cambridge , UK

6. CamPARI Clinic, Addenbrooke’s Hospital and University of Cambridge , Cambridge , UK

Abstract

Abstract Background The accuracy of any radiation therapy delivery is limited by target organ translocation and distortion. Bladder filling is one of the recognised factors affecting prostate translocation and distortion. The purpose of our study was to evaluate the effect of bladder volume on prostate translocation and distortion by using detailed three-dimensional prostate delineation on MRI. Patients and methods Fifteen healthy male volunteers were recruited in this prospective, institutional review board-approved study. Each volunteer underwent 4 different drinking preparations prior to imaging, with MR images acquired pre- and post-void. MR images were co-registered by using bony landmarks and three-dimensional contouring was performed in order to assess the degree of prostate translocation and distortion. According to changes in bladder or rectum distention, subdivisions were made into bladder and rectal groups. Studies with concomitant change in both bladder and rectal volume were excluded. Results Forty studies were included in the bladder volume study group and 8 in the rectal volume study group. The differences in rectal volumes yielded higher levels of translocation (p < 0.01) and distortion (p = 0.02) than differences in bladder volume. Moderate correlation of prostate translocation with bladder filling was shown (r = 0.64, p < 0.01). There was no important prostate translocation when bladder volume change was < 2-fold (p < 0.01). Moderate correlation of prostate distortion with bladder filling was shown (r = 0.61, p < 0.01). Conclusions Bladder volume has a minimal effect on prostate translocation and effect on prostate distortion is negligible. Prostate translocation may be minimalised if there is < 2-fold increase in the bladder volume.

Publisher

Walter de Gruyter GmbH

Subject

Radiology Nuclear Medicine and imaging,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3