Spectrometric Determination of the Total Concentration of Single-Type Analytes Using Conventional Multidimensional Calibrations

Author:

Vlasova I. V.,Vershinin V. I.

Abstract

Abstract Multidimensional calibrations can be used for the spectrometric determination of the total concentration (cΣ) of similar substances; these calibrations relate the generalized signals (AΣ)j measured at different wavelengths (λj) with the concentrations of these analytes (ci) and their absorption coefficients (kij). Such calibrations are conventionally used for the separate determination of analytes, while the ci values are calculated using chemometric algorithms. To find cΣ, one should only take a sum of the found ci values. Despite the simplicity of this type of group analysis, it is rarely used, and its capabilities have not been studied. It is unclear how the accuracy of the cΣ estimate depends on the number of analytical wavelengths (AWLs), the number of standards, and other factors. The purpose of this study was to obtain relevant information using an example of model mixtures of arenes. The absorption spectra of arene mixtures were recorded in the region 230–280 nm, where these spectra are additive. We analyzed 55 hexane solutions containing three to six arenes with a total concentration of 0.1–0.5 mg/mL. The qualitative composition of the model mixtures was considered to compose the matrix of absorption coefficients of individual arenes. The ci values were found by multiple linear regression (MLR, direct calibration). With a sufficiently large number of AWLs, the found ci values were close to zero for arenes absent in the sample and close to the actual ci values for the present arenes. The summation of the found ci gave approximately correct estimates of cΣ (±5%). The single errors of the group analysis were, as a rule, smaller than the errors of the determination of the mixture components. The complication of the model (the introduction of “extra” standards and an increase in the number of AWLs) did not affect the accuracy of the results of group analysis, and the simplification of the model increased errors. If only the most typical standards were used to form the model, the values of kij of which covered the entire range of possible values of kij, the presence of components in the sample that were not taken into account by the simplified model did not lead to a noticeable increase in errors.

Publisher

Pleiades Publishing Ltd

Subject

Analytical Chemistry

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3