Utility of dual-energy contrast-enhanced spectral mammography for the diagnosis of multicentric breast cancer

Author:

Chyornaya A. V.1ORCID,Ulyanova R.  Kh.1ORCID,Krivorotko P.  V.1ORCID,Artemyeva A. S.1ORCID,Bagnenko S. S.1ORCID,Zhiltsova E. K.1ORCID,Novikov S. N.1ORCID,Danilov V. V.1ORCID,Krzhivitskiy P.  I.1ORCID,Semiglazov V. F.1ORCID

Affiliation:

1. N.N. Petrov National Medical Research Center of Oncology, Ministry of Health of Russia

Abstract

Background. Breast cancer (BC) can be unifocal, multifocal, multicentric (MCBC) and bilateral according to number and localization of tumors. MCBC has different clinical and biological characteristics compared to unifocal BC, for example, a higher risk of lymph node involvement, a more aggressive natural history and a worse prognosis. Therefore, accurate diagnosis and detection of MCBC is one of the main tasks of imaging.Objective: to compare diagnostic accuracy of contrast enhanced spectral mammography (CESM) and digital mammography (DM) in the diagnosis of MCBC.Materials and methods. The study included 438 women with suspected BC. The results of DM and CESM were compared with the results of a pathomorphological study performed after surgery or biopsy to assess the effectiveness of imaging modalities. DM was performed for all women using a Senographe DS (GE, USA) unit. CESM was performed after intravenous injection of non-ionic contrast agents using injector with breast compression in the craniocaudal and mediolateral projections. The study was performed for both glands regardless of the location of the suspicious lesion in order to timely diagnose clinically asymptomatic bilateral cancer. The final diagnosis was made based on the results of the pathomorphological examination. MCBC was diagnosed when two or more tumors at a distance of 3 cm or more from each other were detected. Visualization of additional grouped calcifications of malignant type occupying a small portion of breast tissue (more than 15 pieces per 1 sq. cm) was considered as another mammographic sign of MCBC.Results. According to the pathomorphological examination BC was diagnosed in 154 (35 %) women out of 438 examined patients. MCBC was identified in 25 (16 %) of 154 patients. CESM was more effective than DM in detecting MCBC with sensitivity of 88.0 % vs 48.0 % (p = 0.002), accuracy of 92.2 % vs 90.9 %, negative predictive value of 97.6 % vs 90.8 % (p = 0.02), respectively. But the specificity was significantly higher in DM than in CESM – 99.2 % vs 93.0 % (p = 0.009), respectively, and the positive predictive value did not differ significantly (p = 0.12).Conclusion. CESM is a more sensitive method for diagnosing MCBC compared to DM with sensitivity of 88.0 % vs 48.0 %. The high negative predictive value of CESM (97.6 %) confirms the fact that this modality is an effective method for planning surgery and radiation therapy.

Publisher

Publishing House ABV Press

Subject

Pharmacology (medical),Obstetrics and Gynecology,Radiology, Nuclear Medicine and imaging,Oncology,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3