Сontrast enhanced spectral mammography as a tool for accurate diagnosis of cancer on the background of the dense breast tissue

Author:

Chernaya A. V.1ORCID,Ulyanova R. Kh.1ORCID,Bagnenko S. S.1ORCID,Krivorotko P. V.1ORCID,Artemyeva A. S.1ORCID,Zhiltsova E. K.1ORCID,Novikov S. N.1ORCID,Danilov V. V.1ORCID,Krzhivitsky P. I.1ORCID,Meshkova I. E.1ORCID,Zaitsev A. N.1ORCID

Affiliation:

1. N.N. Petrov National Medical Research Center of Oncology

Abstract

Introduction. Differential diagnosis of some pathological processes in the breast is difficult on the background of dense breast tissue. This often leads to false conclusions and to late diagnosis of breast cancer (BC) or unreasonable biopsy in a benign process. 50% of breast cancers detected less than 12 months after elective mammography were associated with high density of breast tissue. An important advantage of contrast enhanced spectral mammography (CESM) is that it does not depend on the size of the lesions and the X-ray density of the breast tissue. Objective. To compare the diagnostic performance of CESM and digital mammography (DM) in detection of breast cancer in a group of women with dense breast tissue.Materials and methods. The data of 438 patients with suspected breast cancer examined from August 2018 to January 2021 were analyzed in the study. The mean age of women was 50 ± 11 years (from 21 to 86 years). In the study group 154 (35%) malignant and 284 (65%) benign lesions were identified. All lesions were histologically verified. Breast tissue density corresponded to types A and B in 161 patients and corresponded to C and D types in 277 patients according to the ACR classification. 154 cases of breast cancer were identified, including 49 patients with density A and B and 105 patients with density C and D types.Results. Sensitivity, specificity and overall accuracy of DM were 85.7%, 87.3%, 86.8%, respectively. Diagnostic performance of CESM significantly higher than of DM with sensitivity, specificity and accuracy of 96.8% (p < 0.001), 93.3% (p = 0.015), 94.5% (p < 0.001), respectively. CESM had high positive and negative predictive values of 88.7% (p = 0.012) and 98.1% (p < 0.001), which exceeded those of DM – 78.6% and 91.9%, respectively. The diagnostic performance of DM and CESM were comparable in women with normal breast density (types A and B according to ACR), but in patients with high breast density (types C and D according to ACR), CESM was significantly more sensitive in detecting breast cancer.Conclusion. Thus, diagnostic efficiency of CESM in detecting breast cancer significantly higher in comparison with digital mammography.

Publisher

Vidar, Ltd.

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3