A modified 3D stereophotogrammetry-based distraction test for assessing lower eyelid tension

Author:

Hou Xiao-Yi, ,Meinke Marius M.,Li Sen-Mao,Lin Ming,Jia Ren-Bing,Guo Yong-Wei,Heindl Ludwig M., , , , , ,

Abstract

AIM: To investigate the reliability of a modified three-dimensional distraction test (3D-DT) and three-dimensional pinch test (3D-PT) for assessing lower eyelid tension (LET). METHODS: A cross-sectional study was conducted among 97 volunteers including 97 eyelids with no history of trauma, tumor, or reconstructive surgeries. Six three-dimensional photographs were acquired for each participant, including two photographs obtained in a neutral position (NP), two using a modified 3D-DT with a 15.9-grammes stainless steel eyelid hook performed, and two using 3D-PT. RESULTS: The mean absolute differences between NP, 3D-DT, and 3D-PT measurements varied between 0.07 and 7.42, 0.10 and 13.10, and 0.07 and 15.97, respectively; technical error of measurement varied between 0.05 and 7.81, 0.09 and 10.19, and 0.07 and 12.47, respectively; and relative error measurements varied between 0.10% and 11.50%, 0.16% and 30.51%, and 0.11% and 38.75%, respectively. For intra-rater reliability, the intraclass correlation coefficients (ICCs) were more than 0.80 in seven out of eight measurements obtained in the NP and 3D-DT, whereas those obtained in the 3D-PT were as low as less than 0.30 by rater 1; the ICCs of all the measurements obtained in all the positions (NP, 3D-DT, and 3D-PT) were more than 0.80 by rater 2. For inter-rater reliability six out of eight NP and 3D-DT measurements had an ICC greater than 0.80, whereas those of 3D-PT measurements were less than 0.30. For intra-method reliability, the ICCs of all the NP measurements were more than 0.87, whereas those of the six 3D-DT measurements and four 3D-PT measurements were more than 0.80. CONCLUSION: Our study results prove that the modified 3D-DT, which involves the use of an eyelid hook, can be a highly reliable method for evaluating LET. Furthermore, this novel and simple method may be utilized as the basis for further investigation and routine pre- and postoperative clinical evaluation.

Publisher

Press of International Journal of Ophthalmology (IJO Press)

Subject

Ophthalmology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3