Abstract
Abstract
Background
Although a portable 3-dimensional (3D) imaging system has been used for periocular measurement analysis, this system has yet to be tested and validated for periocular area and volume measurements.
Objectives
The aim of this study was to define the upper eyelid and upper eyelid fold region through a modified landmark strategy and validate a portable 3D imaging system for area and volume measurements in this periocular region.
Methods
Eighty-one healthy adult Caucasians underwent 3D facial imaging with the VECTRA M3 (static) and VECTRA H2 (portable) 3D imaging systems (Canfield Scientific, Inc., Parsippany, NJ). Subsequently, the upper eyelid and upper eyelid fold regions were selected according to a modified landmark localization strategy. Direct measurements of area and volume were performed to assess intrarater, interrater, intramethod, and intermethod reliability, and to compare the agreement between the 2 devices.
Results
The VECTRA M3 and H2 showed high reliability on upper eyelid area measurements. Excellent intra-, inter-, and intramethod reliability agreements were observed in intraclass correlation coefficient; very good agreement in intrarater reliability was observed in the relative error of measurement (REM) and relative technical error of measurement (rTEM); and good inter- and intramethod reliability were observed in the REM and rTEM. For area measurement of the upper eyelid fold, the intrarater, interrater, and intramethod reliability of the M3 was lower than that of the H2. Both systems had poor intrarater, interrater, and intramethod reliability for volume measurements in the upper eyelid and upper eyelid fold region.
Conclusions
This new portable 3D imaging system achieved excellent or very good reliability values for standardized direct measurements of the upper eyelid and upper eyelid fold region, although volume measurements seem less reliable.
Funder
State Scholarship Fund from the China Scholarship Council
Koeln Fortune Program/Faculty of Medicine, University of Cologne, Germany
Publisher
Oxford University Press (OUP)
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献