Evaluation of the Portable Next-Generation VECTRA H2 3D Imaging System for Measuring Upper Eyelid Area and Volume

Author:

Fan WanlinORCID,Rokohl Alexander CORCID,Maus Julia,Guo Yongwei,Ju Xiaojun,Li Xueting,Wawer Matos Philomena A,Heindl Ludwig M

Abstract

Abstract Background Although a portable 3-dimensional (3D) imaging system has been used for periocular measurement analysis, this system has yet to be tested and validated for periocular area and volume measurements. Objectives The aim of this study was to define the upper eyelid and upper eyelid fold region through a modified landmark strategy and validate a portable 3D imaging system for area and volume measurements in this periocular region. Methods Eighty-one healthy adult Caucasians underwent 3D facial imaging with the VECTRA M3 (static) and VECTRA H2 (portable) 3D imaging systems (Canfield Scientific, Inc., Parsippany, NJ). Subsequently, the upper eyelid and upper eyelid fold regions were selected according to a modified landmark localization strategy. Direct measurements of area and volume were performed to assess intrarater, interrater, intramethod, and intermethod reliability, and to compare the agreement between the 2 devices. Results The VECTRA M3 and H2 showed high reliability on upper eyelid area measurements. Excellent intra-, inter-, and intramethod reliability agreements were observed in intraclass correlation coefficient; very good agreement in intrarater reliability was observed in the relative error of measurement (REM) and relative technical error of measurement (rTEM); and good inter- and intramethod reliability were observed in the REM and rTEM. For area measurement of the upper eyelid fold, the intrarater, interrater, and intramethod reliability of the M3 was lower than that of the H2. Both systems had poor intrarater, interrater, and intramethod reliability for volume measurements in the upper eyelid and upper eyelid fold region. Conclusions This new portable 3D imaging system achieved excellent or very good reliability values for standardized direct measurements of the upper eyelid and upper eyelid fold region, although volume measurements seem less reliable.

Funder

State Scholarship Fund from the China Scholarship Council

Koeln Fortune Program/Faculty of Medicine, University of Cologne, Germany

Publisher

Oxford University Press (OUP)

Subject

General Medicine,Surgery

Reference38 articles.

1. Three-dimensional imaging of the face: a comparison between three different imaging modalities;Verhulst;Aesthet Surg J,2018

2. Three dimensional evaluation of soft tissue after orthognathic surgery;Jung;Head Face Med,2018

3. Frontal soft tissue analysis using a 3 dimensional camera following two-jaw rotational orthognathic surgery in skeletal class III patients;Choi;J Craniomaxillofac Surg,2014

4. [Accuracy of morphological simulation for orthognathic surgery. Assessment of a 3D image fusion software];Terzic;Rev Stomatol Chir Maxillofac Chir Orale,2013

5. Comparison of soft-tissue orbital morphometry in attractive and normal Italian subjects;Sforza;Angle Orthod,2015