Efficient use of automatic exposure control systems in computed tomography requires correct patient positioning

Author:

Gudjonsdottir J.12,Svensson J. R.3,Campling S.3,Brennan P. C.4,Jonsdottir B.1

Affiliation:

1. Röntgen Domus Medica, Reykjavík, Iceland

2. Faculty of Medicine, University of Iceland, Reykjavík, Iceland

3. Faculty of Health and Social Care, Anglia Ruskin University, Cambridge, England, U.K.

4. Diagnostic Imaging, Biological Imaging Research, UCD School of Medicine and Medical Science, University College Dublin, Belfield, Dublin, Ireland

Abstract

Background: Image quality and radiation dose to the patient are important factors in computed tomography (CT). To provide constant image quality, tube current modulation (TCM) performed by automatic exposure control (AEC) adjusts the tube current to the patient's size and shape. Purpose: To evaluate the effects of patient centering on tube current–time product (mAs) and image noise. Material and Methods: An oval-shaped acrylic phantom was scanned in various off-center positions, at 30-mm intervals within a 500-mm field of view, using three different CT scanners. Acquisition parameters were similar to routine abdomen examinations at each site. The mAs was recorded and noise measured in the images. The correlation of mAs and noise with position was calculated using Pearson correlation. Results: In all three scanners, the mAs delivered by the AEC changed with y-position of the phantom ( P<0.001), with correlation values of 0.98 for scanners A and B and −0.98 for scanner C. With x-position, mAs changes were 4.9% or less. As the phantom moved into the y-positions, compared with the iso-center, the mAs varied by up to +70%, −34%, and +56% in scanners A, B, and C, respectively. For scanners A and B, noise in two regions of interest in the lower part of the phantom decreased with elevation, with correlation factors from −0.95 to −0.86 ( P<0.02). In the x-direction, significant noise relationships ( P<0.005) were only seen in scanner A. Conclusion: This study demonstrates that patient centering markedly affects the efficacy of AEC function and that tube current changes vary between scanners. Tube position when acquiring the scout projection radiograph is decisive for the direction of the mAs change. Off-center patient positions cause errors in tube current modulation that can outweigh the dose reduction gained by AEC use, and image quality is affected.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 52 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3