Author:
Benamar M.,Housni A.,Sadiki S.,Amazian K.,Essahlaoui A.,Labzour A.
Abstract
Facing the inflation of the number of irradiating radiological examinations, particularly in Computed Tomography (CT), several countries in the world have resorted to diagnostic reference levels (DRLs), below which dosimetric values must be kept or else corrective actions will be infligated. In Morocco, in the absence of national diagnostic reference levels, we proposed to evaluate the professional practice in CT by recording the radiation doses values delivered to adult patients and comparing the 75th percentile values of the dosimetric indicators (CTDIvol and DLP) per acquisition to the international published values of DRLs, in order to judge the need for optimization of CT examination protocols. The 75th percentile values in terms of CTDIvol for head, chest, abdomen-pelvis, chest-abdomen-pelvis, and lumbar examinations were respectively 57.7, 11.1, 11.3, 11.6 and 20 mGy. In terms of DLP, the 75th percentile values were 1250.4, 392.2, 517.1, 833.27 and 707.37 mGy.cm, for the mentioned type of examinations. These results prompt us to make corrections to the used protocols and to ensure a more rigorous follow-up of the radiation protection principles with particular attention to the principle of dose optimization in order to establish a good practice in CT.
Subject
Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health,Waste Management and Disposal,Safety, Risk, Reliability and Quality,Nuclear Energy and Engineering,Renewable Energy, Sustainability and the Environment
Reference21 articles.
1. ASN. 2019. Arrêté du 23 mai 2019 portant homologation de la décision no 2019-DC-0667 de l’Autorité de sûreté nucléaire du 18 avril 2019 relative aux modalités d’évaluation des doses de rayonnements ionisants délivrées aux patients lors d’un acte de radiologie, de pratiques interventionnelles radioguidées ou de médecine nucléaire et à la mise à jour des niveaux de référence diagnostiques associés. Journal officiel de la République française, 30 mai 2019, Texte 31 sur 209.
2. Benaidja A. 2011. Influence des paramètres d’aquisition sur la dose délivrée aux patients lors d’un examen scanographique en acquisition hélicoïdale. Magister, Alger: Université des sciences et de la technologie Houari Boumediène.
3. Frequent Chest X-Ray Fluoroscopy and Breast Cancer Incidence among Tuberculosis Patients in Massachusetts
4. Des doses patients excessives en scanographie : de nouvelles préoccupations
5. Chapitre XI : Doses délivrées au patient en scanographie (scanner)
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献