Contribution of CAD to the Sensitivity for Detecting Lung Metastases on Thin-Section CT – A Prospective Study with Surgical and Histopathological Correlation

Author:

Meybaum Christian1,Graff Mareike2,Fallenberg Eva Maria3,Leschber Gunda2,Wormanns Dag14

Affiliation:

1. Department of Radiology, ELK Berlin Chest Hospital, Germany

2. Dept. of Thoracic Surgery, ELK Berlin Chest Hospital, Germany

3. Department of Radiology, Charité University Medicine Berlin, Germany

4. Department of Clinical Radiology, University Hospital Münster, Germany

Abstract

Purpose To assess the sensitivity of radiologists and a CAD system for the detection of lung metastases on thin-section computed tomographic (CT) scans prior to pulmonary metastasectomy. Materials and Methods All patients scheduled for resection of lung metastases were eligible for this prospective single-center trial. 95 patients with 115 surgical procedures (pulmonary metastasectomy using thoracotomy) were included. An experienced radiologist examined the CT scans for pulmonary metastases and documented his findings. A commercial CAD system was used as a second reader; additional CAD findings were recorded. A comparison of the sensitivity of the radiologist alone and with CAD was performed. Intraoperatively surgeons tried to identify the documented lesions and resected them as well as additionally palpable lesions. The standard of reference consisted of surgery and histopathology. Follow-up information for radiologically detected lesions missed during surgery was sought. Results 693 lesions (262 metastases) were detected radiologically or surgically, 646 of them were resected. The sensitivity of radiologists without CAD was 67.5 % for all lesions (87.4 % for metastases). CAD highly significantly (p < 0.001) increased the sensitivity to 77.9 % (92.7 %). During surgery, 143 additional lesions (19 metastases) were detected. 49 radiologically detected lesions were not palpable during surgery: 4 metastases, 5 benign lesions, and 40 lesions of an unknown nature. Conclusion CAD provides significant additional sensitivity for detecting lung metastases using MDCT compared to the performance of a radiologist alone. CT reveals a relevant number of non-palpable pulmonary lesions. Key Points:  Citation Format

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3