Abstract

Abstract Background Various extratympanic recording electrodes have been used to make electrocochleography (ECochG) and auditory brainstem response (ABR) measurements in clinics, translational research, and basic science laboratories. However, differences may exist in ECochG and ABR measurements depending on the different types of extratympanic electrodes that are used. Purpose The purpose of this research is to compare simultaneously recorded ECochG and ABR responses using three different extratympanic electrodes. This research helps clinicians and researchers to understand how electrode types and recording sites influence EcochG and ABR results. In addition, our findings could provide more normative data to the ECochG and ABR literature as well as give perspective on a preferred electrode approach when performing simultaneous ECochG and ABR testing. Research Design Ours was a repeated-measures study with measurements being made from individual participants on two separate sessions. Study Sample Twenty young adult females with normal hearing. Procedure A three-channel recording system was used to simultaneously record ECochG and ABR measurements in response to alternating polarity click stimuli. In each session, measurements were simultaneously recorded with a TipTrode electrode and one of the tympanic membrane (TM) electrodes. Data Collection and Analysis Suprathreshold summating potential (SP) and action potential (AP) of the ECochG and waves I, III, and V of the ABR, and threshold responses (AP and wave V) were identified. Results Compared with the ear canal TipTrode electrode, TM electrodes yielded suprathreshold amplitudes that were larger than those from the ear canal electrode, smaller SP–AP ratios, lower AP thresholds, and less variability. These findings can help guide choices made by clinicians, translational investigators, and basic science researchers on which type of extra-tympanic electrode to use for their intended purpose.

Publisher

Georg Thieme Verlag KG

Subject

Speech and Hearing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3