Autologous Blood Pleurodesis: What Is the Optimal Time Interval and Amount of Blood?

Author:

Campisi Alessio12ORCID,Dell'Amore Andrea3,Zhang Yonghui1,Gu Zhitao1,Ciarrocchi Angelo Paolo2,Faccioli Eleonora3,Bertolaccini Luca4,Rea Federico3,Stella Franco2,Fang Wentao1

Affiliation:

1. Department of Thoracic Surgery, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China

2. Department of Thoracic Diseases, Thoracic Surgery Unit, University of Bologna, G.B. Morgagni-L. Pierantoni Hospital, Forlì, Italy

3. Department of Cardiothoracic Surgery and Vascular Sciences, Division of Thoracic Surgery, Padua University Hospital, University of Padua, Via Giustiniani 1, Padua (PD), Italy

4. Department of Thoracic Surgery, European Institute of Oncology IRCCS, Milan, Italy

Abstract

Abstract Background Air leak is the most common complication after lung resection and leads to increased length of hospital (LOH) stay or patient discharge with a chest tube. Management by autologous blood patch pleurodesis (ABPP) is controversial because few studies exist, and the technique has yet to be standardized. Methods We retrospectively reviewed patients undergoing ABPP for prolonged air leak (PAL) following lobectomy in three centers, between January 2014 and December 2019. They were divided into two groups: Group A, 120 mL of blood infused; Group B, 60 mL. Propensity score-matched (PSM) analysis was performed, and 23 patients were included in each group. Numbers and success rates of blood patch, time to cessation of air leak, time to chest tube removal, reoperation, LOH, and complications were examined. Univariate and multivariate analysis of variables associated with an increased risk of air leak was performed. Results After the PSM, 120 mL of blood is statistically significant in reducing the number of days before chest tube removal after ABPP (2.78 vs. 4.35), LOH after ABPP (3.78 vs. 10.00), and LOH (8.78 vs. 15.17). Complications (0 vs. 4) and hours until air leak cessation (6.83 vs. 3.91, range 1–13) after ABPP were also statistically different (p < 0.05). Air leaks that persisted for up to 13 hours required another ABPP. No patient had re-operation or long-term complications related to pleurodesis. Conclusion In our experience, 120 mL is the optimal amount of blood and the procedure can be repeated every 24 hours with the chest tube clamped.

Publisher

Georg Thieme Verlag KG

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3