Adjusting Insert Thickness and Tibial Slope Do Not Correct Internal Tibial Rotation Loss Caused by PCL Resection: In Vitro Study of a Medial Constraint TKA Implanted with Unrestricted Calipered Kinematic Alignment

Author:

Nedopil Alexander J.1ORCID,Thadani Peter J.2,McCoy Thomas H.3,Howell Stephen M.4ORCID,Hull Maury L.5ORCID

Affiliation:

1. Department of Orthopaedic Surgery, University of Würzburg, Würzburg, Germany

2. Department of Orthopedic Surgery, Illinois Bone & Joint Institute, Libertyville, Illinois

3. Unova Hip and Knee Center, Lady Lake, Florida

4. Department of Biomedical Engineering, University of California, Davis, California

5. Department of Mechanical Engineering, University of California, Davis, California

Abstract

AbstractMost medial stabilized (MS) total knee arthroplasty (TKA) implants recommend excision of the posterior cruciate ligament (PCL), which eliminates the ligament's tension effect on the tibia that drives tibial rotation and compromises passive internal tibial rotation in flexion. Whether increasing the insert thickness and reducing the posterior tibial slope corrects the loss of rotation without extension loss and undesirable anterior lift-off of the insert is unknown. In 10 fresh-frozen cadaveric knees, an MS design with a medial ball-in-socket (i.e., spherical joint) and lateral flat insert was implanted with unrestricted calipered kinematic alignment (KA) and PCL retention. Trial inserts with goniometric markings measured the internal–external orientation relative to the femoral component's medial condyle at maximum extension and 90 degrees of flexion. After PCL excision, these measurements were repeated with the same insert, a 1 mm thicker insert, and a 2- and 4-mm shim under the posterior tibial baseplate to reduce the tibial slope. Internal tibial rotation from maximum extension and 90 degrees of flexion was 15 degrees with PCL retention and 7 degrees with PCL excision (p < 0.000). With a 1 mm thicker insert, internal rotation was 8 degrees (p < 0.000), and four TKAs lost extension. With a 2 mm shim, internal rotation was 9 degrees (p = 0.001) and two TKAs lost extension. With a 4 mm shim, internal rotation was 10 degrees (p = 0.002) and five TKAs lost extension and three had anterior lift-off. The methods of inserting a 1 mm thicker insert and reducing the posterior slope did not correct the loss of internal tibial rotation after PCL excision and caused extension loss and anterior lift-off in several knees. PCL retention should be considered when using unrestricted calipered KA and implanting a medial ball-in-socket and lateral flat insert TKA design, so the progression of internal tibial rotation and coupled reduction in Q-angle throughout flexion matches the native knee, optimizing the retinacular ligaments' tension and patellofemoral tracking.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3