Factors Associated with Umbilical Venous Catheter Malposition in Newborns: A Tertiary Center Experience

Author:

Soonsawad Sasivimon12,Kieran Emily A.1,Ting Joseph Y.13,AlonsoPrieto Esther13,Panczuk Julia K.1

Affiliation:

1. Division of Neonatology, Department of Pediatrics, BC Women's and Children's Hospital and the University of British Columbia, Canada

2. Ramathibodi Medical School, Chakri Naruebodindra Medical Institute, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Samut Prakan, Thailand

3. BC Children's Hospital Research Institute, Vancouver, BC, Canada

Abstract

Objective Umbilical venous catheters (UVC) are widely used in neonatal intensive care (NICU). Noncentral catheter position is known to be associated with multiple adverse complications; however, risk factors for catheter malposition are unclear. This work aimed to identify clinical risk factors and complications associated with UVC malposition in neonates admitted in an NICU. Study Design A retrospective chart review was performed of inborn babies admitted to BC Women's Hospital NICU with UVC inserted in their first 7 days between July 2016 and June 2018. Infant and maternal demographic, radiograph, UVC-related data, and complications were reviewed. Results A total of 257 infants had UVC placed; 158 (61%) and 99 (39%) were in central and noncentral positions after initial placement, respectively. Of initially central-placed UVCs, a further 35 (22%) were pulled back or migrated to malposition on follow-up X-ray. Multivariable logistic regression analysis revealed the use of larger UV (5 Fr) catheter (odds ratio [OR]: 2.5, 95% confidence interval [CI]: 1.1–5.6, p = 0.026) and escalation of respiratory support mode (OR: 1.7, 95% CI: 1.0–2.8, p = 0.049) as significant predictors of catheter malposition. Conclusion Noncentral UVC position as well as migration were common after initial placement in this cohort. The use of larger size UV catheters and increasingly invasive respiratory support were risk factors associated with higher incidence of UVC malposition. Ongoing surveillance of UVC position is thus recommended. Key Points

Publisher

Georg Thieme Verlag KG

Subject

Obstetrics and Gynaecology,Pediatrics, Perinatology, and Child Health

Reference30 articles.

1. Standardizing umbilical catheter usage in preterm infants;S Shahid;Pediatrics,2014

2. Umbilical vein catheterization under electrocardiogram guidance;B CH Tsui;Paediatr Anaesth,2005

3. Rare but fatal complication of umbilical venous catheterization;A M Al Nemri;Congenit Heart Dis,2006

4. Central venous catheter-related tachycardia in the newborn: case report and literature review;A Amer;Case Rep Med,2016

5. Pleural effusion caused by a malpositioned umbilical venous catheter in a neonate;T Abiramalatha;BMJ Case Rep,2015

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司