Double Bipolar Sealing of the Pulmonary Artery Improves the Bursting Pressures

Author:

vom Hofe Burkhardt1,Pehl Anika2,Bartsch Detlef1,Kirschbaum Andreas1

Affiliation:

1. Department of Visceral, Thoracic and Vascular Surgery, University Hospital Giessen and Marburg GmbH (UKGM), Marburg, Germany

2. Institute of Pathology, University Hospital Giessen and Marburg GmbH (UKGM), Marburg, Germany

Abstract

Background In every anatomic lung resection, branches of the pulmonary artery have to be divided. In open surgery, this can be done with ligatures or staplers. In endoscopic surgery, only an endostapler can be used. By routing we ligate the vessels double. Bipolar sealing had yielded promising results, so we wanted to know if we can improve the bursting pressures especially in case of larger vessels by double sealing. Methods Experiments were performed on preparations of the left pulmonary artery extracted at the slaughterhouse. A pressure sensor was implanted at the central end to provide digital measurement of the pneumatic load on the vessel seal and thus establish bursting pressure in each case. Vessels were sealed with MARSEAL 5 (Gebrüder Martin GmbH & Co KG, Tuttlingen, Germany) and SealSafe G3 electric current. The vessels investigated were separated into three sizes: 1 to 6 mm, 7 to 12 mm, and >12 mm. The groups (n = 12 in each) were investigated for each vessel size—Group 1: ligature; Group 2: single seal; Group 3: double seals separated by gap of 0.5 cm; and Group 4: double seals separated by gap of 1.0 cm. Mean bursting pressure (mbar) was calculated for each group. Differences between groups were calculated with Mann–Whitney U test; differences with p < 0.05 were considered significant. Results The ligated vessels in the 1 to 6 mm group showed the highest bursting pressures (mean 515.7 ± 39.6 mbar). Mean bursting pressure in the single seal group was 231.6 ± 47.5 mbar. This was not significantly different from the group with double seals placed 0.5 cm apart. However, bursting pressures were significantly higher in the group with double seals placed 1 cm apart (p < 0.001). Mean value in this case was 308.5 ± 44.5 mbar. In the 7 to 12 mm vessels, mean bursting pressure was highest with ligation at 361 ± 67.1 mbar but was significantly higher in both groups with double bipolar seals (180.3 ± 52.1 mbar with 0.5-cm separation and 277.0 ± 64.5 with 1-cm separation) than in the single seal group (102.7 ± 16.1 mbar). In large vessels (>12 mm), mean bursting pressures were low (66.3 ± 12.7 mbar) with single seals but were significantly higher with double seals (162.3 ± 35.8 mbar [0.5-cm separation] and 137.3 ± 22.9 mbar [1-cm separation]). Conclusions In the ex vivo model of the pulmonary artery, double seals revealed significantly higher bursting pressures than single seals. If there is enough vessel length, the two seals should be placed 1 cm apart.

Publisher

Georg Thieme Verlag KG

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3