Effect of Plate Type and Working Length on a Synthetic Compressed Juxta-Articular Fracture Model

Author:

Bird Guy1,Glyde Mark1,Hosgood Giselle1,Hayes Alex2,Day Rob2

Affiliation:

1. College of Veterinary Medicine, Murdoch University, Perth, Australia

2. Department of Medical Engineering and Physics, Royal Perth Hospital, Perth, Australia

Abstract

Abstract Objective This investigation compared the biomechanical properties of a 2.0 mm locking compression notched head T-plate (NHTP) and 2.0 mm straight locking compression plate (LCP), in a compressed, short, juxta-articular fragment fracture model. Methods Two different screw configurations were compared for the NHTP and LCP, modelling short (configuration 1) and long working length (configuration 2). Constructs were tested in compression, perpendicular and tension four-point bending and torsion. Plate surface strain was measured at 12 regions of interest using three-dimensional digital image correlation. Stiffness and strain were compared. Results The LCP was stiffer than the NHTP in all three planes of bending (p < 0.05). The NHTP was stiffer than the LCP in torsion (p < 0.05). The NHTP had greater strain than the LCP during compression bending and torsion (p < 0.0005). The short working length NHTP was stiffer in all three planes of bending and in torsion (p < 0.05) than the longer working length. The short working length LCP was stiffer in compression bending and in torsion (p < 0.05) than the longer working length. The long working length showed greater strain than the short working length at multiple regions of interest. Conclusion In this experimental model of a compressed transverse fracture with a juxta-articular 9 mm fragment, a 2.0 mm LCP with two hybrid screws in the short fragment was stiffer than a 2.0 mm NHTP with three locking screws in the short fragment in three planes of bending but not torsion. Extending the working length of each construct reduced construct stiffness and increased plate strain.

Publisher

Georg Thieme Verlag KG

Reference39 articles.

1. Locking compression plate stabilization of 20 distal radial and ulnar fractures in toy and miniature breed dogs;S Gibert;Vet Comp Orthop Traumatol,2015

2. Open reduction and cranial bone plate fixation of fractures involving the distal aspect of the radius and ulna in miniature- and toy-breed dogs: 102 cases (2008-2015);R De Arburn Parent;J Am Vet Med Assoc,2017

3. Clinical outcomes and complications after open reduction and internal fixation utilizing conventional plates in 65 distal radial and ulnar fractures of miniature- and toy-breed dogs;T Aikawa;Vet Comp Orthop Traumatol,2018

4. Hybrid locked plating of osteoporotic fractures of the humerus;M J Gardner;J Bone Joint Surg Am,2006

5. Locked plating in practice: indications and current concepts;J Scolaro;Univ Pennsylvania Orthop J,2011