Differences in Trochlear Morphology from Native Using a Femoral Component Interfaced with an Anatomical Patellar Prosthesis in Kinematic Alignment and Mechanical Alignment

Author:

Hull Maury L.123ORCID,Howell Stephen M.1ORCID

Affiliation:

1. Department of Biomedical Engineering, University of California Davis, Davis, California

2. Department of Mechanical Engineering, University of California Davis, Davis, California

3. Department of Orthopaedic Surgery, University of California Davis, Davis, California

Abstract

AbstractPatellofemoral complications following total knee arthroplasty can be traced in part to alignment of the femoral component. Kinematic alignment (KA) and mechanical alignment (MA) use the same femoral component but align the component differently. Our objective was to determine differences in trochlear morphology from native for a femoral component interfaced with an anatomical patellar prosthesis in KA and MA. Ten three-dimensional femur-cartilage models were created by combining computed tomography and laser scans of native human cadaveric femurs free of skeletal abnormalities. The femoral component was positioned using KA and MA. Measurements of the prosthetic and native trochlea were made along the arc length of the native trochlear groove and differences from native were computed for the medial-lateral and radial locations of the groove and sulcus angle. Mean medial-lateral locations of the prosthetic groove were within 1.5 and 3.5 mm of native for KA and MA, respectively. Mean radial locations of the prosthetic groove were as large as 5 mm less than native for KA and differences were greater for MA. Sulcus angles of the prosthetic trochlea were 10 degrees steeper proximally, and 10 degrees flatter distally than native for both KA and MA. Largest differences from native occurred for radial locations and sulcus angles for both KA and MA. The consistency of these results with those of other fundamentally different designs which use a modified dome (i.e., sombrero hat) patellar prosthesis highlights the need to reassess the design of the prosthetic trochlea on the part of multiple manufacturers worldwide.

Funder

Medacta, Inc.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

Reference26 articles.

1. Malrotation causing patellofemoral complications after total knee arthroplasty;R A Berger;Clin Orthop Relat Res,1998

2. Patellofemoral instability in total knee arthroplasty;J L Briard;J Arthroplasty,1989

3. Surface damage of patellar components used in total knee arthroplasty;M A Conditt;J Bone Joint Surg Am,2005

4. The failed total knee arthroplasty: evaluation and etiology;M H Gonzalez;J Am Acad Orthop Surg,2004

5. Why knees fail;K G Vince;J Arthroplasty,2003

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3