Differences in Trochlear Morphology of a New Femoral Component Designed for Kinematic Alignment from a Mechanical Alignment Design

Author:

Hull Maury L.1,Simileysky Alexander2,Howell Stephen M.2ORCID

Affiliation:

1. Department of Biomedical Engineering, Department of Mechanical Engineering, Department of Orthopaedic Surgery, University of California Davis, Davis, CA 95616, USA

2. Department of Biomedical Engineering, University of California Davis, Davis, CA 95616, USA

Abstract

Because kinematic alignment (KA) aligns femoral components in greater valgus and with less external rotation than mechanical alignment (MA), the trochlear groove of an MA design used in KA is medialized, which can lead to complications. Hence, a KA design has emerged. In this study, our primary objective was to quantify differences in trochlear morphology between the KA design and the MA design from which the KA design evolved. The KA and MA designs were aligned in KA on ten 3D femur-cartilage models. Dependent variables describing the morphology of the trochlea along the anterior flange, which extends proximal to the native trochlea, and along the arc length of the native trochlea, were determined, as was flange coverage. Along the anterior flange, the KA groove was significantly lateral proximally by 10 mm and was significantly wider proximally by 5 mm compared to the MA design (p < 0.0001). Along the arc length of the native trochlea, the KA groove was significantly lateral to the MA design by 4.3 mm proximally (p ≤ 0.0001) and was significantly wider proximally by 19 mm than the MA design. The KA design reduced lateral under-coverage of the flange from 4 mm to 2 mm (p < 0.0001). The KA design potentially mitigates risk of patellofemoral complications by lateralizing and widening the groove to avoid medializing the patella for wide variations in the lateral distal femoral angle, and by widening the flange laterally to reduce under-coverage. This information enables clinicians to make informed decisions regarding use of the KA design.

Funder

Medacta USA, Inc.

Publisher

MDPI AG

Reference29 articles.

1. Patellar complications following total knee arthroplasty: A review of the current literature;Assiotis;Eur. J. Orthop. Surg. Traumatol.,2019

2. Component rotation and anterior knee pain after total knee arthroplasty;Barrack;Clin. Orthop. Relat. Res.,2001

3. Surface damage of patellar components used in total knee arthroplasty;Conditt;J. Bone Joint Surg.,2005

4. Malrotation causing patellofemoral vomplications after total knee arthroplasty;Berger;Clin. Orthop. Relat. Res.,1998

5. The failed total knee arthroplasty: Evaluation and etiology;Gonzalez;J. Am. Acad. Orthop. Surg.,2004

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3