Radiographic and Biomechanical Assessment of Three Implant Designs for Canine Cementless Total Hip Replacement

Author:

Worden Natalie J.1ORCID,Ash Kristian J.1,Ordway Nathaniel R.2ORCID,Miller Mark A.2,Mann Kenneth A.2,VanDeventer Gretchen M.1,Valenzano Dominick M.1,Hart Robert3,Kayano Mitsunori4,Hayashi Kei1

Affiliation:

1. Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York, United States

2. Department of Orthopedic Surgery, SUNY Upstate Medical University, Syracuse, New York, United States

3. Department of Orthopedic Surgery, Animal Medical Center, New York, New York, United States

4. Department of Veterinary Medicine, Research Center for Global Agromedicine, Obihiro University of Agriculture and Veterinary Medicine, Obihiro, Japan

Abstract

Abstract Objective The aim of this study was to evaluate the relationship between radiographic fit/fill measurements and biomechanical performance of three canine cementless total hip implant designs using an in vitro biomechanical testing protocol that replicates compression and torsion. Study Design Eighteen (six/group) canine cadaveric femurs were implanted with one of three cementless total hip implant designs: (1) collarless, (2) collared or (3) lateral bolt stems. Femoral length, canal flare index (CFI), canal fill, stem fit, stem level and stem angle were measured as independent variables. Biomechanical performance was tested using physiological, non-destructive gait loading (loading protocols) and destructive testing (failure protocols). Results During loading protocols, compressive stiffness was influenced by stem level (p < 0.05) and torsional stiffness was influenced by stem level and CFI for collarless stems (p < 0.05). During failure protocols, peak load was influenced by mediolateral (ML) stem angle (p < 0.05) and CFI (p < 0.01) for collarless stems and CFI for lateral bolt stems (p < 0.05). Peak torque was influenced by ML stem angle, craniocaudal stem angle and CFI for collarless stems (p < 0.05) and average ML fill for collared stems (p < 0.05). Conclusion Biomechanical performance of collarless stems in cementless hip arthroplasty is more impacted by radiographic fit/fill than lateral bolt and collared stems. As a result, collarless stems may be more dependent on preoperative fit and intraoperative precision.

Publisher

Georg Thieme Verlag KG

Subject

General Veterinary,Animal Science and Zoology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3