Effect of Stem Positioning on Biomechanical Performance of a Novel Cementless Short-Stem Canine Total Hip Implant

Author:

Worden Natalie Jean1ORCID,Ash Kristian J.1,Ordway Nathaniel R.2ORCID,Miller Mark2,Mann Kenneth A.2,VanDeventer Gretchen M.1,Valenzano Dominick M.1,Kayano Mitsunori3,Tomihari Mizuki3,Hayashi Kei1

Affiliation:

1. Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York, United States

2. Department of Orthopedic Surgery, SUNY Upstate Medical University, Syracuse, New York, United States

3. Research Center for Global Agromedicine, Obihiro University of Agriculture and Veterinary Medicine, Obihiro, Hokkaido, Japan

Abstract

Abstract Objective The aim of this study was to evaluate the effect of stem positioning on the biomechanical performance of a novel, collared, short-stem total hip implant under compression and torsion ex vivo. Study Design Six canine cadaveric femurs were implanted with a collared short-stem femoral implant. Canal flare index (CFI), stem angle, absolute and relative cut heights and relative size were measured radiographically and used as independent variables. Biomechanical performance of the construct was evaluated using physiologic loading (loading) and supraphysiologic loading (failure) protocols. Results During loading protocols, compressive stiffness was influenced by absolute cut height (p = 0.018). During failure protocols, peak torque was influenced by CFI (p = 0.004) and craniocaudal relative size (p = 0.005). Peak load and torsional stiffness were not impacted by any of the radiographic variables (p > 0.05). Three of six femurs developed longitudinal fractures originating at the medial calcar at the time of failure. Conclusion The biomechanical performance of the collared short-stem implant was positively impacted by preserving more of the femoral neck, having a higher CFI and using a smaller implant size relative to the femoral neck isthmus.

Publisher

Georg Thieme Verlag KG

Subject

General Veterinary,Animal Science and Zoology

Reference32 articles.

1. Total hip replacement in three cats: surgical technique, short-term outcome and comparison to femoral head ostectomy;W D Liska;Vet Comp Orthop Traumatol,2009

2. Total hip replacement as a treatment option for capital physeal fractures in dogs and cats;R H Kalis;Vet Surg,2012

3. Treatment of avascular necrosis of the femoral head in small dogs with micro total hip replacement;D A Jankovits;Vet Surg,2012

4. Aseptic loosening of the femoral implant after cemented total hip arthroplasty in dogs: 11 cases in 10 dogs (1991-1995);M R Edwards;J Am Vet Med Assoc,1997

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3