Reducing Surgeon's Physical Stress in Minimally Invasive Neurosurgery

Author:

Nakayashiki Atsushi1,Kawaguchi Tomohiro1,Nakagawa Atsuhiro1,Mochizuki Fusako1,Furukawa Hiroaki1,Nagai Arata1,Suematsu Takuya1,Tominaga Teiji1

Affiliation:

1. Department of Neurosurgery, Tohoku University Graduate School of Medicine, Sendai, Japan

Abstract

Background and Study Aims Various minimally invasive approaches are used in neurosurgery. Surgeons must perform nondynamic fine movements in a narrow corridor, so specially designed surgical devices are essential. Unsophisticated instruments may pose potential hazards. The purpose of this study was to assess the factors associated with muscle fatigue during minimally invasive neurosurgery and to investigate whether physical stress can be reduced by refining the devices used. Material and Methods Four physical aspects of a handpiece were investigated: torque of conduits (0.20, 0.28, and 0.37 kgf*cm), shape of hand grip (five types), angle of the nozzle (0, 20, and 40 degrees), and weight balance (neutral, proximal, and distal). To evaluate muscle fatigue, surface electromyography was recorded from the extensor carpi radialis muscle and flexor carpi radialis muscle during a geometric tracing task. The maximum voluntary contraction (MVC) of each muscle and %MVC (muscle contraction during a task/MVC × 100) were used as the indexes of muscle fatigue. Results The shape of the hand grip significantly reduced %MVC, which is associated with muscle fatigue. The torque of conduits and angle of the nozzle tended to reduce muscle fatigue but not significantly. Weight balance did not affect muscle fatigue. Based on these results, we made two refined models: model α (torque of conduits 0.2 kgf*cm, angle of nozzle 20 degrees, neutral balance, hand grip with a 2.9 × 2.0-cm oval section with angled finger rest), and model β (torque of conduits 0.2 kgf*cm, angle of nozzle 20 degrees, neutral balance, hand grip with a 2.9-cm round section with a curved finger rest). The %MVC was significantly decreased with both types (p < 0.05 and p < 0.01, respectively), indicating reduction of muscle fatigue. Conclusions The geometrically refined surgical device can improve muscle load during surgery and reduce the surgeon's physical stress, thus minimizing the risk of complications.

Publisher

Georg Thieme Verlag KG

Subject

Neurology (clinical),Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3