Influence of video-based feedback on self-assessment accuracy of endoscopic skills: a randomized controlled trial

Author:

Scaffidi Michael1,Walsh Catharine234,Khan Rishad1,Parker Colleen1,Al-Mazroui Ahmed1,Abunassar Michael1,Grindal Alexander1,Lin Peter1,Wang Christopher1,Bechara Robert5,Grover Samir1

Affiliation:

1. Division of Gastroenterology, St. Michael’s Hospital, University of Toronto, Toronto, Canada

2. Department of Paediatrics, University of Toronto, Toronto, Canada

3. Department of Medicine, University of Toronto, Toronto, Canada

4. Division of Gastroenterology, Hepatology and Nutrition, Hospital for Sick Children, University of Toronto, Toronto, Canada

5. Department of Medicine, Queen’s University, Kingston, Ontario, Canada

Abstract

Abstract Background and study aims Novice endoscopists are inaccurate in self-assessment of procedures. One means of improving self-assessment accuracy is through video-based feedback. We aimed to determine the comparative effectiveness of three video-based interventions on novice endoscopists’ self-assessment accuracy of endoscopic competence. Materials and methods Novice endoscopists (performed < 20 previous procedures) were recruited. Participants completed a simulated esophagogastroduodenoscopy (EGD) on a virtual reality simulator. They were then randomized to one of three groups: self-video review (SVR), which involved watching a recorded video of their own performance; benchmark review (BVR), which involved watching a video of a simulated EGD completed by an expert; and self- and benchmark video (SBVR), which involved both videos. Participants then completed two additional simulated EGD cases. Self-assessments were conducted immediately after the first procedure, after the video intervention and after the additional two procedures. External assessments were conducted by two experienced endoscopists, who were blinded to participant identity and group assignment through video recordings. External and self-assessments were completed using the global rating scale component of the Gastrointestinal Endoscopy Competency Assessment Tool (GiECAT GRS). Results Fifty-one participants completed the study. The BVR group had significantly improved self-assessment accuracy in the short-term, compared to the SBVR group (P = .005). The SBVR group demonstrated significantly improved self-assessment accuracy over time (P = .016). There were no significant effects of group or of time for the SVR group. Conclusions Video-based interventions, particularly combined use of self- and benchmark video review, can improve accuracy of self-assessment of endoscopic competence among novices.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370