Liver Stiffness Assessed by Ultrasound Shear Wave Elastography from General Electric Accurately Predicts Clinically Significant Portal Hypertension in Patients with Advanced Chronic Liver Disease

Author:

Stefanescu Horia12,Rusu Corina32,Lupsor-Platon Monica4,Nicoara Farcau Oana32,Fischer Petra32,Grigoras Crina12,Horhat Adelina12,Stancu Oana52,Ardelean Andreea12,Tantau Marcel3,Badea Radu4,Procopet Bogdan132

Affiliation:

1. Hepatology Department, Regional Institute of Gastroenterology and Hepatology, Cluj Napoca, Romania

2. Liver Research Club, Cluj-Napoca, Romania

3. 3rd Medical Clinic, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania

4. Medical Imaging Department, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania

5. Central Military Hospital, Carol Davila University of Medicine and Pharmacy, Bucharest, Romania

Abstract

AbstractPurpose Clinically significant portal hypertension (CSPH) is responsible for most of the complications in patients with cirrhosis. Liver stiffness (LS) measurement by vibration-controlled transient elastography (VCTE) is currently used to evaluate CSPH. Bi-dimensional shear wave elastography from General Electric (2D-SWE.GE) has not yet been validated for the diagnosis of PHT. Our aims were to test whether 2D-SWE.GE-LS is able to evaluate CSPH, to determine the reliability criteria of the method and to compare its accuracy with that of VCTE-LS in this clinical setting.Materials and Methods Patients with chronic liver disease referred to hepatic catheterization (HVPG) were consecutively enrolled. HVPG and LS by both VCTE and 2D-SWE.GE were performed on the same day. The diagnostic performance of each LS method was compared against HVPG and between each other.Results 2D-SWE.GE-LS was possible in 123/127 (96.90 %) patients. The ability to record at least 5 LS measurements by 2D-SWE.GE and IQR < 30 % were the only features associated with reliable results. 2D-SWE.GE-LS was highly correlated with HVPG (r = 0.704; p < 0.0001), especially if HVPG < 10 mmHg and was significantly higher in patients with CSPH (15.52 vs. 8.14 kPa; p < 0.0001). For a cut-off value of 11.3 kPa, the AUROC of 2D-SWE.GE-LS to detect CSPH was 0.91, which was not inferior to VCTE-LS (0.92; p = 0.79). The diagnostic accuracy of LS by 2D-SWE.GE-LS to detect CSPH was similar with the one of VCTE-LS (83.74 % vs. 85.37 %; p = 0.238). The diagnostic accuracy was not enhanced by using different cut-off values which enhanced the sensitivity or the specificity. However, in the subgroup of compensated patients with alcoholic liver disease, 2D-SWE.GE-LS classified CSPH better than VCTE-LS (93.33 % vs. 85.71 %, p = 0.039).Conclusion 2D-SWE.GE-LS has good accuracy, not inferior to VCTE-LS, for the diagnosis of CSPH.

Publisher

Georg Thieme Verlag KG

Subject

Radiology Nuclear Medicine and imaging

Reference31 articles.

1. The management of portal hypertension: Rational basis, available treatments and future options;J Bosch;J Hepatol,2008

2. The Cost-Effectiveness of Hepatic Venous Pressure Gradient Monitoring in the Prevention of Recurrent Variceal Hemorrhage;L E Targownik;Am J Gastroenterol,2004

3. The clinical use of HVPG measurements in chronic liver disease;J Bosch;Nat Rev Gastroenterol Hepatol Nature Publishing Group,2009

4. EASL-ALEH Clinical Practice Guidelines: Non-invasive tests for evaluation of liver disease severity and prognosis;L Castera;J Hepatol,2015

5. Expanding consensus in portal hypertension Report of the Baveno VI Consensus Workshop: Stratifying risk and individualizing care for portal hypertension;R D Franchis;J Hepatol European Association for the Study of the Liver,2015