Automated Light Transmission Aggregometry with and without Platelet Poor Plasma Reference: A Method Comparison

Author:

Sachs Ulrich J.12,Röder Lida2,Cooper Nina2,Radon Christian3,Kolde Hans-Jürgen4

Affiliation:

1. Department of Thrombosis and Haemostasis, Giessen University Hospital, Giessen, Germany

2. Institute for Clinical Immunology, Transfusion Medicine, and Haemostaseology, Justus Liebig University, Giessen, Germany

3. Behnk Elektronik, Norderstedt, Germany

4. Consulting Diagnostics, Seefeld, Germany

Abstract

Abstract Background Light transmission aggregometry (LTA) is considered the gold standard for the evaluation of platelet function but is labor-intensive and involves numerous manual steps. Automation may contribute to standardization. Here, we evaluate the performance characteristics of a new automated instrument, Thrombomate XRA (TXRA), and compare it against a manual instrument (PAP-8). Materials and Methods Leftover blood samples from blood donors or patients were tested in parallel with identical reagents and in identical concentrations both manually using PAP-8 and automated on the TXRA. In addition to precision and method comparison, an additional evaluation was performed on the TXRA against “virtual” platelet-poor plasma (VPPP) based on artificial intelligence. The main focus was on comparing the maximum aggregation (MA%) values. Results Precision for MA% ranged from 1.4 to 4.6% on TXRA for all reagents. Normal ranges for 100 healthy blood donors on both instruments were in a similar range for all reagents, with a tendency to slightly higher values with TXRA. Most agonists resulted in normally distributed MA%. Comparing 47 patient samples on both devices showed a good correlation for both slope and MA% with some differences in individual samples with epinephrine and TRAP. Correlation between the TXRA measurement against PPP and “virtual” PPP demonstrated excellent correlation. Reaction signatures of both devices were very similar. Conclusion TXRA provides reproducible LTA results that correlate with an established manual method when tested against PPP or VPPP. Its ability to perform LTA only from platelet-rich plasma without requiring autologous PPP simplifies LTA. TXRA is an important step not only for further standardizing LTA but also for a more widespread use of this important method.

Funder

Behnk Elektronik GmbH & Co.KG, 22851 Norderstedt, Germany

Publisher

Georg Thieme Verlag KG

Subject

General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3