Validity evidence for simulator-based obstetric ultrasound competency assessment tool: a multi-center study

Author:

Zhao Yongfeng1ORCID,Zhou Ping1,Zhu Wenhui1,Xiao Jidong1,Liu Wengang1,Luo Yingchun2,Zhang Junhui2,Yang Lan3,Xu Yan3,Tang Xiaohong4

Affiliation:

1. Ultrasound, Central South University Third Xiangya Hospital, Changsha, China

2. Ultrasound, Hunan Provincial Maternal and Child Health Care Hospital, Changsha, China

3. Ultrasound, Nanjing Drum Tower Hospital, Nanjing, China

4. Clinical Skill Center, Central South University Third Xiangya Hospital, Changsha, China

Abstract

Abstract Purpose To collect validity evidence for a simulator-based obstetric ultrasound competency assessment tool (OUCAT). Methods 89 sonographers from three centers (XY, MC, DT), including novices (n=21), experienced trainees (n=44), and experts (n=24), participated in the competency assessment. Validity evidence of OUCAT was collected according to Standards for Educational and Psychological Testing. Content validity was ensured by reviewing guidelines and reaching expert consensus. The response process was ensured via training raters. Internal structure was explored through internal consistency, inter-rater reliability, and test-retest reliability. Relations to other variables were explored by comparing OUCAT scores of sonographers with different experience. Evidence for consequences was collected by determining the pass/fail level. Results OUCAT included 123 items, of which 117 items could effectively distinguish novices from experts (P<0.05). The internal consistency was represented by the Cronbach’s α coefficient (0.978). The inter-rater reliability was high, with XY being 0.868, MC being 0.877, and DT being 0.937 (P<0.001). Test-retest reliability was 0.732 (P=0.001). The performance of experts was significantly better than experienced trainees, and the performance of experienced trainees was significantly better than novices (70.3±10.7 vs. 39.8±15.0 vs. 20.5±10.6, P<0.001). The pass/fail level determined by contrast group method was 45 points. The passing rate of novices, experienced trainees and experts was 0% (0/21), 31.8% (14/44), and 100% (24/24), respectively. Conclusion Simulator-based OUCAT exhibits good reliability and validity in assessing obstetric ultrasound skills.

Funder

Project of the 14th five year plan of Educational Science in Hunan Province

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Ultrasound supports clinical decision-making in determining the Sanders’ skeletal maturity score of the hand;International Orthopaedics;2024-04-24

2. Potenzial von Simulatoren in der Ultraschalldiagnostik;Ultraschall in der Medizin - European Journal of Ultrasound;2024-04

3. Simulation-based education in ultrasound – diagnostic and interventional abdominal focus;Ultraschall in der Medizin - European Journal of Ultrasound;2024-03-21

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3