Different Settings of Nonsynchronized Bilevel Nasal Continuous Positive Airway Pressure and Respiratory Function in Preterm Infants: A Pilot Study

Author:

Cavigioli Francesco1,Bresesti Ilia12,Gatto Sara1,Castoldi Francesca1,Gavilanes Danilo3,Gazzolo Diego4,Agosti Massimo2,Kramer Boris3,Lista Gianluca1

Affiliation:

1. Division of Neonatology, “V.Buzzi” Children's Hospital, ASST FBF-Sacco, Milan, Italy

2. Department of Medicine and Surgery, University of Insubria, Varese, Italy

3. Department of Pediatrics, School for Oncology and Developmental Biology (GROW), Maastricht University Medical Center, Maastricht, The Netherlands

4. Neonatal Intensive Care Unit, G. D'Annunzio University, Chieti, Italy

Abstract

Objective With this study, we evaluated the short-term effects of different modes and settings of noninvasive respiratory support on gas exchange, breathing parameters, and thoracoabdominal synchrony in preterm infants in the acute phase of moderate respiratory distress syndrome. Study Design A feasibility crossover trial was conducted in neonates < 32 weeks' gestation on nasal continuous positive airway pressure (n-CPAP) or bilevel n-CPAP. Infants were delivered the following settings in consecutive order for 10 minutes each: • n-CPAP (5 cm H2O) • bilevel n-CPAP 1 (Pres low = 5 cm H2O, Pres high = 7 cm H2O, T-high = 1 second, rate = 30/min) • n-CPAP (5 cm H2O) • bilevel n-CPAP 2 (Pres low = 5 cm H2O, Pres high = 7 cm H2O, T-high = 2 second, rate = 15/min) • n-CPAP (5 cm H2O). During each phase, physiologic parameters were recorded; the thoracoabdominal synchrony expressed by the phase angle (Φ) and other respiratory patterns were monitored by noncalibrated respiratory inductance plethysmography. Results Fourteen preterm infants were analyzed. The mean CPAP level was significantly lower in the n-CPAP period compared with bilevel n-CPAP 1 and 2 (p = 0.03). Higher values were achieved with bilevel n-CPAP 2 (6.2 ± 0.6 vs. 5.7 ± 0.5 cm H2O, respectively; p < 0.05). No statistical difference in the Φ was detected, nor between the three settings. Conclusion Our study did not show any superiority of bilevel n-CPAP over n-CPAP. However, nonsynchronized bilevel n-CPAP might be helpful when additional pressure is needed. Key Points

Publisher

Georg Thieme Verlag KG

Subject

Obstetrics and Gynecology,Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3