Objective. To determine whether noninvasive, nasal synchronized intermittent mandatory ventilation (nSIMV) improves the likelihood that very low birth weight infants will be successfully extubated. Methods. Infants of <1251-g birth weight who were due to be extubated before 6 weeks of age were eligible once they were receiving <35% oxygen and were on a ventilator rate of <18 breaths per minute (bpm). Extubation was performed following intravenous loading with aminophylline, after a successful trial of 12 hours of endotracheal synchronized intermittent mandatory ventilation at a rate of 8. Infants were randomized to either nasal continuous positive airway pressure (nCPAP) at 6 cm H2O or nSIMV after extubation. nSIMV was commenced at a rate of 12 bpm with pressure on the ventilator set to achieve a delivered pressure of at least 12 cm H2O and a peak end expiratory pressure of 6 cm H2O. Continuous recording for diagnosis of apnea was performed for 72 hours after extubation. Objective criteria for failure of extubation were as follows: a Paco2 >70; Fio2 >0.7; or severe recurrent apnea (>2 apneas requiring intermittent positive-pressure ventilation in 24 hours or >6 apneas >20 seconds per day). The study ended after 72 hours postextubation or when infants satisfied failure criteria. A sample size of 54 was determined by power analysis. Results. Mean birth weight (831 standard deviation [SD]: 193 g) and gestation (26.3 SD: 1.8 weeks) did not differ between groups. Mean age at extubation was 7.6 (SD: 9.7) days, range 1 to 40 days. The nSIMV group had a lower incidence of failed extubation 4/27 compared with the continuous positive airway pressure group, 12/27. This was attributable to both a decreased incidence of apnea and a decreased incidence of hypercarbia. There was no increase in the incidence of abdominal distension or feeding intolerance. Discussion. nSIMV is effective in preventing extubation failure in very low birth weight infants in the first 72 hours after extubation. Noninvasive ventilation may have other roles in the care of the very low birth weight infant.

Publisher

American Academy of Pediatrics (AAP)

Subject

Pediatrics, Perinatology and Child Health

Cited by 198 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Measuring practice preference variation for quality improvement in neonatal respiratory care;Journal of Perinatology;2024-04-08

2. Noninvasive Ventilation;Critical Care Nursing Clinics of North America;2024-03

3. Invasive and Noninvasive Ventilation Strategies;Principles of Neonatology;2024

4. Neonatal Respiratory Therapy;Avery's Diseases of the Newborn;2024

5. Optimising success of neonatal extubation: Respiratory support;Seminars in Fetal and Neonatal Medicine;2023-10

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3