Dynamic 4D-CT Angiography for Guiding Transarterial Chemoembolization: Impact on the Reduction of Contrast Material, Operator Radiation Exposure, Catheter Consumption, and Diagnostic Confidence

Author:

Albrecht Moritz1,Vogl Thomas1,Wichmann Julian1,Martin Simon1,Scholtz Jan-Erik1,Fischer Sebastian1,Hammerstingl Renate1,Harth Marc1,Nour-Eldin Nour-Eldin1,Thalhammer Axel1,Zangos Stephan1,Bauer Ralf1

Affiliation:

1. Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Germany

Abstract

Purpose This study was carried out to investigate the impact of abdominal dynamic four-dimensional CT angiography (4D-CTA) for guiding transarterial chemoembolization (TACE) on the amount of contrast material used, operator radiation exposure, catheter consumption, and diagnostic confidence. Materials and Methods Written consent was waived for this IRB-approved retrospective study. 29 patients (20 men; mean age: 65.7 ± 11.5 years) with malignant liver lesions underwent 4D-CTA, prior to initial TACE. Time-resolved volume-rendering technique (VRT), maximum-intensity projection (MIP), and multiplanar reconstruction (MPR) series were reconstructed, enabling a direct selective catheterization of the tumor-supplying artery without prior conventional digital subtraction angiography (DSA). 29 patients (16 men; mean age: 69.4 ± 13.9) who underwent traditional TACE served as the control group. The amount of administered contrast media, operator radiation exposure, and catheter consumption during TACE were compared. Two radiologists assessed diagnostic confidence in the exclusion of portal vein thrombosis. Results 4D-CTA TACE resulted in a significant reduction in the amount of contrast media used, compared to traditional TACE (–61.0 ml/ –66.3 % intra-arterial, –12.8 ml/ –13.8 % overall; P < 0.001). The dose-area product indicating operator radiation exposure during intervention was reduced by 50.5 % (P < 0.001), and 0.7 fewer catheters on average were used (P = 0.063), while 4D-CTA data was available to guide TACE. Diagnostic confidence in the exclusion of portal vein thrombosis was significantly enhanced by 4D-CTA, compared to traditional DSA images (scores, 3.9 and 2.4, respectively; P < 0.001). Conclusion Dynamic 4D-CTA enables TACE with a substantially reduced amount of contrast material, decreases operator radiation exposure, and increases diagnostic confidence in the exclusion of portal vein thrombosis. Key points  Citation Format

Publisher

Georg Thieme Verlag KG

Subject

Radiology Nuclear Medicine and imaging

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Access and Material;Transarterial Chemoembolization (TACE);2023

2. Benefits of adrenal venous sampling with preoperative four-dimensional CT imaging;Acta Radiologica;2022-08-09

3. Imaging of peripheral vascular malformations — current concepts and future perspectives;Molecular and Cellular Pediatrics;2021-12

4. Strahlenexposition bei häufigen interventionellen Eingriffen der Leber im Vergleich;Der Radiologe;2020-08-20

5. Peripheral Vascular Anomalies – Essentials in Periinterventional Imaging;RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren;2019-10-17

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3