Pulsed X-ray source with the pulse duration of 50 ns and the peak power of 70 MW for capturing moving objects

Author:

Komarskiy Alexander Alexandrovich1,Korzhenevskiy Sergey Romanovich1,Ponomarev Andrey Viktorovich1,Komarov Nikita Alexandrovich1

Affiliation:

1. The Institute of Electrophysics, Russian Academy of Sciences, Ekaterinburg, Russia

Abstract

BACKGROUND: Traditionally, X-ray systems for capturing moving objects consist of a continuous X-ray source and a detector that operates at a predetermined frame rate. OBJECTIVE: This study investigates the possibility of using pulsed X-ray source with an inductive energy storage device and a semiconductor opening switch for shooting moving objects. METHODS: The study uses a high-voltage pulse generator that has the following parameters namely, the pulse voltage amplitude up to 320 kV, the pulse current up to 240 A, the current pulse duration of about 50 ns, and the pulse repetition rate up to 2 kHz. The duration and intensity of glow for standard CsI:Tl and Gd2O2S:Tb X-ray phosphors after their irradiation with X-ray flashes of about 50 ns duration are investigated. After X-ray radiation is converted into light, the signal is recorded using semiconductor detectors. We acquired several images of an object moving at a speed of about 20 m/s. A semiconductor detector with phosphor, which operates in the mode of continuous signal accumulation, is used. RESULTS: When using the pulsed X-ray source and phosphors with a short afterglow, the individual frames can be obtained at the pulse repetition rate of several kilohertz, and the detector does not contain the residual luminescence from the previous frame by the arrival of the next frame. CONCLUSIONS: The X-ray source shows good pulse-to-pulse reproducibility of X-rays, and can be used to capture objects in motion at a frame rate of several kHz.

Publisher

IOS Press

Subject

Electrical and Electronic Engineering,Condensed Matter Physics,Radiology Nuclear Medicine and imaging,Instrumentation,Radiation

Reference15 articles.

1. A review of airport dual energy X-ray baggage inspection techniques: Image enhancement and noise reduction;Khan;Journal of X-ray Science and Technology,2020

2. Jamet F. and Thomer G. , Flash Radiography, Elsevier, 1976.

3. Mesyats G.A. and Proskurovsky D.I. , Pulsed electrical discharge in vacuum, Springer-Verlag Berlin, Heidelberg, 1989.

4. A novel nanosecond semiconductor opening switch for megavolt repetitive pulsed power technology: Experiment and Aplications, Proc. IX IEEE Intern;Kotov;Pulsed Power Conf Albuquerque,1993

5. Pulsed power technology based on semiconductor opening switches: A review;Rukin;Review of Scientific Instruments,2020

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3