Comparison of the finger plethysmography derived stroke volumes by Nexfin CO Trek and suprasternal aortic Doppler derived stroke volume measurements in adults with myalgic encephalomyelitis/chronic fatigue syndrome and in healthy controls

Author:

van Campen C. (Linda) M.C.1,Verheugt Freek W.A.2,Rowe Peter C.3,Visser Frans C.1

Affiliation:

1. Stichting CardioZorg, Hoofddorp, The Netherlands

2. Radboud UMC, Nijmegen, The Netherlands

3. Department of Paediatrics, Johns Hopkins University School of Medicine, Baltimore, MD, USA

Abstract

BACKGROUND: Finger plethysmography derived stroke volumes are frequently measured during tilt table testing. There are two algorithms to determine stroke volumes: Modelflow and Nexfin CO Trek. Most tilt studies used Modelflow, while there are differences between the two algorithms. OBJECTIVE: To compare stroke volume indices by Nexfin CO Trek (SVINexfinCOTrek) with suprasternal Doppler derived SVI (SVIDoppler) in healthy controls (HC) and myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS) patients during tilt testing. These patients may have a large SVI decrease during the tilt enabling a large range of SVI to be studied. METHODS: One hundred and fifty-four patients and 39 HC with a normal tilt test were included. Supine and end-tilt SVIDoppler and SVINexfinCOTrek were compared using the Bland-Altman analysis. Also, the effect of calibrating supine SVINexfinCOTrek to SVIDoppler was studied. RESULTS: Supine and end-tilt SVINexfinCOTrek were significantly higher than SVIDoppler: both P< 0.005. Bias, limits of agreement, and percent error (PE) were high with PE’s between 37 and 43%. The calibration procedure resulted in an acceptable variance with a PE of 29%. CONCLUSIONS: SVINexfinCOTrek overestimates stroke volumes compared to SVIDoppler, leading to high PE’s. Calibration reduced variance to an acceptable level, allowing SVINexfinCOTrek to be used for assessment of SVI changes during tilt testing.

Publisher

IOS Press

Subject

Health Informatics,Biomedical Engineering,Information Systems,Biomaterials,Bioengineering,Biophysics

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3