Stroke Volume Estimation from Respiratory Inductive Plethysmography: Double Empirical Decomposition

Author:

Abdulhay Enas1ORCID,Gumery Pierre-Yves2,Ilango R.3,Hariharasitaraman S.4,Thilagaraj M.5,Arunkumar N.6,Ramirez-Gonzalez Gustavo7

Affiliation:

1. Biomedical Engineering Department, Jordan University of Science and Technology, Irbid 22110, Jordan

2. PRETA, TIMC, Grenoble-Alpes University, Grenoble, France

3. Department of Electrical and Electronics Engineering, K.Ramakrishnan College of Engineering, Trichy, India

4. School of Computing Science and Engineering, VIT Bhopal University, Bhopal, Madhya Pradesh, India

5. Department of Electronics and Instrumentation Engineering, Karpagam College of Engineering, Coimbatore, India

6. Department of Biomedical Engineering, Rathinam Technical Campus, Coimbatore, India

7. Departamento de Telematica, Universidad del Cauca, Cauca, Colombia

Abstract

In this study, we have developed a “double-empirical mode decomposition algorithm” to estimate cardiac stroke volume from respiratory inductive plethysmography (RIP) signals. The algorithm consists of first an ensemble empirical mode decomposition (EEMD) to extract the cardiorespiratory components. Then, it is followed by an empirical mode decomposition (EMD) to extract only the cardiac components. This double approach permits (a) solving problems of mixing between cardiac and respiratory components (mode and scale mixing), (b) cardiogenic oscillations extraction in the respiratory inductive plethysmography signal, and (c) subsequent estimation of stroke volume. The algorithm is applied to simulated and real RIP signals. The simulated signals are generated by a cardiorespiratory model previously published by the authors. The real signals are measured via a developed inductive vest. In the real case, the values of estimated stroke volumes are compared to the values obtained by thoracocardiographic filter-based method. In the simulated case, the values are compared to the simulated cardiac activity. The results of comparison through Bland and Altman indicate an error lying in the range ±10%. In contrast to thoracocardiography, the proposed method consists of a promising tool for continuous noninvasive adaptive cardiac monitoring that does not need adjusting parameters or cut-off based on ECG. Also, in comparison to echocardiography and impedance-based methods, it does not necessitate the presence of an expert and is not too sensitive to current penetration.

Funder

French Ministry of Higher Education

Publisher

Hindawi Limited

Subject

Computer Science Applications,Software

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3