Development of a computational tool for estimating computed tomography dose parameters

Author:

Almohiy Hussain M.1,Hussein Khalid I.12,Alqahtani Mohammed S.1,Rawashdeh Mohammad3,Elshiekh Elhussaien14,Alshahrani Madshush M.5,Saad Mohammed16,Foley Shane7,Saade Charbel8

Affiliation:

1. Department of Radiological Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia

2. Department of Medical Physics and Instrumentation, National Cancer Institute, University of Gezira, Wad Medani, Sudan

3. Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan

4. Radiation Safety Institute, Sudan Atomic Energy Commission, Khartoum, Sudan

5. Department of Radiology, Khamis Mushayt General Hospital, Khamis Mushayt, Saudi Arabia

6. Department of Physics, Faculty of Science, Mansoura University, Mansoura, Egypt

7. Radiography & Diagnostic Imaging, School of Medicine, University College Dublin, Dublin, Ireland

8. Department of Medical Imaging Sciences, American University of Beirut Medical Centre, Beirut, Lebanon

Abstract

BACKGROUND: Computed Tomographic (CT) imaging procedures have been reported as the main source of radiation in diagnostic procedures compared to other modalities. To provide the optimal quality of CT images at the minimum radiation risk to the patient, periodic inspections and calibration tests for CT equipment are required. These tests involve a series of measurements that are time consuming and may require specific skills and highly-trained personnel. OBJECTIVE: This study aims to develop a new computational tool to estimate the dose of CT radiation outputs and assist in the calibration of CT scanners. It may also provide an educational resource by which radiological practitioners can learn the influence of technique factors on both patient radiation dose and the produced image quality. METHODS: The computational tool was developed using MATLAB in order to estimate the CT radiation dose parameters for different technique factors. The CT radiation dose parameters were estimated from the calibrated energy spectrum of the x-ray tube for a CT scanner. RESULTS: The estimated dose parameters and the measured values utilising an Adult CT Head Dose Phantom showed linear correlations for different tube voltages (80 kVp, 100 kVp, 120 kVp, and 140 kVp), with R2 nearly equal to 1 (0.99). The maximum differences between the estimated and measured CTDIvol were under 5 %. For 80 kVp and low tube currents (50 mA, 100 mA), the maximum differences were under 10%. CONCLUSIONS: The prototyped computational model provides a tool for the simulation of a machine-specific spectrum and CT dose parameters using a single dose measurement.

Publisher

IOS Press

Subject

Electrical and Electronic Engineering,Condensed Matter Physics,Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Reference32 articles.

1. Projected cancer risks from computed tomographic scans performed in the United States in 2007;Berrington de González;Arch Intern Med,2009

2. Spiral computerized tomography in the evaluation of acute flank pain: a replacement for excretory urography;Fielding;The Journal of Urology,1997

3. A comparison of noncontrast computerized tomography with excretory urography in the assessment of acute flank pain;Niall;The Journal of Urology

4. Can noncontrast helical computed tomography replace intravenous urography for evaluation of patients with acute urinary tract colic?;Chen;The Journal of Emergency Medicine,1999

5. Added value of ultra–low-dose computed tomography, dose equivalent to chest X-ray radiography, for diagnosing chest pathology;Lucia;Journal of Thoracic Imaging,2019