Feasibility study of using virtual non-contrast images derived from dual-energy CT to replace true non-contrast images in patients diagnosed with papillary thyroid carcinoma

Author:

Zhou Jiang1,Zhou Yan1,Hu Hao1,Shen Mei-Ping2,Ge Ying-Qian3,Tao Xin-Wei3,Xu Xiao-Quan1,Su Guo-Yi1,Wu Fei-Yun1

Affiliation:

1. Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China

2. Department of Thyroid Surgery, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China

3. Siemens Healthineers, Shanghai, China

Abstract

OBJECTIVE: To assess the feasibility of using virtual non-contrast (VNC) images derived from dual-energy computed tomography (DECT) to replace true non-contrast (TNC) images of papillary thyroid carcinoma (PTC) patients. METHODS: Images of 96 PTC patients were retrospectively analyzed. TNC images were acquired under the single-energy mode of DECT after the plain scanning. The arterial and venous phase VNC (VNC-a and VNC-v) images were generated by the post-processing algorithm from the arterial phase and venous phase of contrast-enhanced CT images, respectively. Mean attenuation values, image noise, number and length of calcification were measured. Radiation dose was also calculated. Last, subjective score of image quality was evaluated by a 5-point scale. RESULTS: Signal-to-noise ratio (SNR) of each tissue in TNC images is significantly higher than that of VNC images (p<0.050). Contrast-to-noise ratio (CNR) of fat, muscle, thyroid nodules and internal carotid artery in TNC images is significantly higher than that of VNC images, while CNR in TNC images is lower for cervical vertebra (p<0.001). Calcification is detected on TNC images of 44 patients, while it is omitted on VNC images of 14 patients (31.8%). The subjective score of TNC images is higher than VNC images (p<0.001). The effective dose reduction is 47.6% by avoiding plain scanning. CONCLUSIONS: Considering the different attenuation value, SNR, CNR and especially reduced detection rate of calcification, we deem that VNC images cannot be directly used to replace TNC images in PTC patients, despite the reduced radiation dose.

Publisher

IOS Press

Subject

Electrical and Electronic Engineering,Condensed Matter Physics,Radiology Nuclear Medicine and imaging,Instrumentation,Radiation

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3