Performance of virtual non-contrast images generated on clinical photon-counting detector CT for emphysema quantification: proof of concept

Author:

Jungblut Lisa1,Sartoretti Thomas1,Kronenberg Daniel1,Mergen Victor1,Euler Andre1,Schmidt Bernhard2,Alkadhi Hatem1,Frauenfelder Thomas1,Martini Katharina1

Affiliation:

1. Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland

2. Siemens Healthcare GmbH, Computed Tomography, Forchheim, Germany

Abstract

Objective: To evaluate the performance of virtual non-contrast images (VNC) compared to true non-contrast (TNC) images in photon-counting detector computed tomography (PCD-CT) for the evaluation of lung parenchyma and emphysema quantification. Methods: 65 (mean age 73 years; 48 male) consecutive patients who underwent a three-phase (non-contrast, arterial and venous) chest/abdomen CT on a first-generation dual-source PCD-CT were retrospectively included. Scans were performed in the multienergy (QuantumPlus) mode at 120 kV with 70 ml intravenous contrast agent at an injection rate of 4 ml s−1. VNC were reconstructed from the arterial (VNCart) and venous phase (VNCven). TNC and VNC images of the lung were assessed quantitatively by calculating the global noise index (GNI) and qualitatively by two independent, blinded readers (overall image quality and emphysema assessment). Emphysema quantification was performed using a commercially available software tool at a threshold of −950 HU for all data sets. TNC images served as reference standard for emphysema quantification. Low attenuation values (LAV) were compared in a Bland–Altman plot. Results: GNI was similar in VNCart (103.0 ± 30.1) and VNCven (98.2 ± 22.2) as compared to TNC (100.9 ± 19.0, p = 0.546 and p = 0.272, respectively). Subjective image quality (emphysema assessment and overall image quality) was highest for TNC (p = 0.001), followed by VNCven and VNCart. Both, VNCart and VNCven showed no significant difference in emphysema quantification as compared to TNC (p = 0.409 vs. p = 0.093; respectively). Conclusion: Emphysema evaluation is feasible using virtual non-contrast images from PCD-CT. Advances in knowledge: Emphysema quantification is feasible and accurate using VNC images in PCD-CT. Based on these findings, additional TNC scans for emphysema quantification could be omitted in the future.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3