Assessing the Stability of Photon-Counting CT: Insights from a Two-Year Longitudinal Study

Author:

Liu Leening P.ORCID,Pasyar Pouyan,Liu Fang,Cao QuyORCID,Sandvold Olivia F.ORCID,Sahbaee Pooyan,Shinohara Russell T.ORCID,Litt Harold I.ORCID,Noël Peter B.ORCID

Abstract

AbstractBackgroundAmong the advancements in computed tomography (CT) technology, photon-counting computed tomography (PCCT) stands out as a significant innovation, providing superior spectral imaging capabilities while simultaneously reducing radiation exposure. Its long-term stability is important for clinical care, especially longitudinal studies, but is currently unknown.PurposeThis study sets out to comprehensively analyze the long-term stability of a first-generation clinical PCCT scanner.Materials and MethodsOver a two-year period, from November 2021 to November 2023, we conducted weekly identical experiments utilizing the same multi-energy CT protocol. These experiments included various tissue-mimicking inserts to rigorously assess the stability of Hounsfield Units (HU) and image noise in Virtual Monochromatic Images (VMIs) and iodine density maps. Throughout this period, notable software and hardware modifications were meticulously recorded. Each week, VMIs and iodine density maps were reconstructed and analyzed to evaluate quantitative stability over time.ResultsSpectral results consistently demonstrated the quantitative stability of PCCT. VMIs exhibited stable HU values, such as variation in relative error for VMI 70 keV measuring 0.11% and 0.30% for single-source and dual-source modes, respectively. Similarly, noise levels remained stable with slight fluctuations linked to software changes for VMI 40 and 70 keV that corresponded to changes of 8 and 1 HU, respectively. Furthermore, iodine density quantification maintained stability and showed significant improvement with software and hardware changes, especially in dual-source mode with nominal errors decreasing from 1.44 to 0.03 mg/mL.ConclusionThis study provides the first long-term reproducibility assessment of quantitative PCCT imaging, highlighting its potential for the clinical arena. This study indicates its long-term utility in diagnostic radiology, especially for longitudinal studies.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3