Microfluidic coagulation assay for monitoring anticoagulant therapy in acute stroke patients

Author:

Bluecher Annemarie,dos Santos Sascha Meyer,Ferreirós Nerea,Labocha Sandra,Meyer dos Santos Isabel Maria Rodrigues,Picard-Willems Bettina,Harder Sebastian,Singer Oliver C.

Abstract

SummaryReliable detection of anticoagulation status in patients treated with non-vitamin K antagonist oral anticoagulants (NOACs) is challenging but of importance especially in the emergency setting. This study evaluated the potential of a whole-blood clotting time assay based on Surface Acoustic Waves (SAW-CT) in stroke-patients. The SAW-technology was used for quick and homogenous recalcification of whole blood inducing a surface-activated clotting reaction quantified and visualised by real-time fluorescence microscopy with automatic imaging processing. In 20 stroke or transient ischaemic attack (TIA)-patients taking NOACs kinetics of SAW-CT were assessed and correlated to other coagulation parameters (PT, aPTT) and NOAC-plasma concentration measured by tandem mass spectrometry (LC-MS/MS). In 225 emergency patients with suspicion of acute stroke or TIA, SAW-CT values were assessed. Mean (± SD) SAW-CT in non-anticoagulated stroke patients (n=180) was 124 s (± 21). In patients on dabigatran or rivaroxaban, SAW-CT values were significantly higher 2 and 8 hours (h) after intake rising up to 267 seconds (s) (dabigatran, 2 h after intake) and 250 s (rivaroxaban, 8 h after intake). In patients on apixaban, SAW-CT values were only moderately increased 2 h after intake (SAW-CT 153 s). In emergency patients, SAW-CT values were significantly higher in NOAC and vitamin K antagonist (VKA)-treated as compared to non-anticoagulated patients. In conclusion, the SAW-CT assay is capable to monitor anticoagulant level and effect in patients receiving dabigatran, rivaroxaban and the VKA phenprocoumon. It has a limited sensitivity for apixaban-detection. If specific SAW-CT results were used as cut-offs, SAW-CT yields high diagnostic accuracy to exclude relevant rivaroxaban and dabigatran concentrations in strokepatients.

Funder

Bayer Vital, Leverkusen, Germany

Publisher

Georg Thieme Verlag KG

Subject

Hematology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3