Performance Characteristics of DOAC Dipstick in Determining Direct Oral Anticoagulants in Urine

Author:

Harenberg Job12ORCID,Martini Andrea3,Du Shanshan1,Krämer Sandra1,Weiss Christel3,Hetjens Svetlana3

Affiliation:

1. Ruprecht-Karls-University, Heidelberg, Germany

2. DOASENSE GmbH, Heidelberg, Germany

3. Department of Medical Statistics, Medical Faculty Mannheim, Ruprecht-Karls-University Heidelberg, Mannheim, Germany

Abstract

Testing for direct oral anticoagulants (DOACs) in patient urine may facilitate medical treatment decisions. The aim of this study was to investigate interobserver variability by 2 independent observers compared to laboratory staff in the visual interpretation of factor Xa (DXI) and thrombin inhibitors (DTI) using the DOAC Dipstick test. We also examined whether test pads reacted to other anticoagulants and abnormal urine colors. The colors of the DOAC Dipstick direct factor Xa inhibitor and thrombin inhibitor pads were interpreted with 100% accuracy (95% confidence interval 0.862 to 1.000) for urine samples from persons treated with apixaban (n = 26), rivaroxaban (n = 24), and dabigatran (n = 29) and without anticoagulant therapy (n = 29). The factor Xa and thrombin inhibitor pads did not interact with heparin, nadroparin, fondaparinux, or coumadin. One µg/mL r-Hirudin and 6 µg/mL argatroban interacted with the DTI pad; however, this is unlikely to cause clinical problems because dabigatran is unlikely to be administered together with r-Hirudin and argatroban in clinical circumstances. Abnormal urine color was reliably detected by the urine color pad, so can prevent false interpretation of the DOAC Dipstick pad colors. In conclusion, we have demonstrated that interobserver variability when interpreting the DOAC Dipstick test strip is low and that factor Xa and thrombin inhibitor pads do not react to other anticoagulants such as heparins and coumadin. R-Hirudin and argatroban can be detected by the thrombin inhibitor pad and abnormal urine colors can be detected by the urine color pad to prevent false interpretation of the results in patient urine samples.

Funder

DOASENSE GmbH, Germany

Publisher

SAGE Publications

Subject

Hematology,General Medicine

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3